Reference

12
Documents
40
Entities
682
Chunks

Documents

DocumentSourceUpdated
📄 Clients/Reference/_other-info.md manual 2026-05-02 16:48:52.553055 View →
📄 Clients/Reference/_equipment-info.md manual 2026-05-02 16:48:50.608065 View →
📄 Clients/Reference/_network-info.md manual 2026-05-02 16:48:42.957992 View →
📄 Reference/Manuals/Allen_Bradley/Panelview/2711p-um008_-en-p.pdf manual 2026-03-10 23:00:10.665441 View →
📄 Reference/Manuals/Short Circuit Calculatons Book.pdf manual 2026-03-10 15:20:10.883328 View →
📄 Reference/Manuals/Eaton/VFD/powerxl-dm1-quick-start-guide-PUB53696-rel2021-05-20.pdf manual 2026-03-06 03:43:23.874814 View →
📄 Reference/Manuals/Allen_Bradley/L320ER/5069-in013_-en-p.pdf manual 2026-03-06 03:43:21.417934 View →
📄 Reference/Manuals/Aerzen/AERtronic_20_ModbusEthernetIP-Liste-V108-en.pdf manual 2026-03-06 03:43:17.386491 View →
📄 Reference/Manuals/Grundfos/98393459_0323_Modbus_for_Grundfos_boosters_IO_GB_2.pdf manual 2026-03-06 03:42:49.591130 View →
📄 Reference/Manuals/RFScada/Modbus_section_from_RFScada4_16Manual.pdf manual 2026-03-06 03:42:19.192684 View →
📄 Reference/Manuals/Aerzen/0618-BCH-6_rev-_AERtronic_20_EtherNet-IP_Integration_Instruction_for_Allen_Bradley_-_Rockwell_PLC_-_WIP.pdf manual 2026-03-06 03:32:42.750641 View →
📄 Reference/Manuals/Allen_Bradley/PlantPAX/V4_10/PlantPax_4_10.pdf manual 2026-03-06 03:32:20.939153 View →

Entities

TypeKeyValueConfidenceEvidence
_no_entities too_short 0%
_no_entities none_found 0%
server RS-232 connector 4 pin Molex socket J15 95% RS-232 connector being a 4 pin Molex type socket on the lower right hand side of the board marked J15
server Modbus connection baud rate 9600 baud, no parity, one stop bit 95% The connection data rate is usually fixed at 9600 baud, no parity with one stop bit
server RS-485 connector 3 pin terminal block J16 95% RS-485 connecter is a three pin terminal block marked J16
server AERtronic 2.0 LAN2 port LAN2 port 90% LAN 2 is a dedicated Aerzen service port
server Default Static IP Address 192.168.1.245 90% Static IP address: Settable in ethernet communication parameters group. (Default 192.168.1.245)
server Modbus master unit ID 0 90% To determine the type of unit read register 608, if it is zero this unit is the RFScada system ‘master’
server Modbus slave unit ID range 1 to 31 90% When connected via Modbus to a slave unit (i.e. the units id is 1 to 31)
server Default Static Gateway 192.168.1.1 90% Static default gateway: Settable in ethernet communication parameters group. (Default 192.168.1.1)
server AERtronic 2.0 LAN1 port LAN1 port 90% Ethernet/IP connection to Allen Bradley/Rockwell PLC MUST be made through the LAN1 port connection
server Default Static Subnet Mask 255.255.255.0 90% Static subnet mask: Settable in ethernet communication parameters group. (Default 255.255.255.0)
server Ethernet Ports Ethernet Ports 80% Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
server AERtronic module IP address IP address of the AERtronic 2.0 module 80% Name and set the IP address of the module so that it matches the IP address on the AERtronic 2.0
system Grundfos Control Unit CU 352 100% CU 352 Grundfos Control Unit used in Hydro MPC booster systems
system Grundfos Control Unit CU 354 100% CU 354 Grundfos Control Unit used in Demand Driven Distribution
system Product Name AERTronic2 100% AERTronic2 Modbus and Ethernet/IP Table
system Product Name CompactLogix 5380 Controllers 100% CompactLogix 5380 Controllers Installation Instructions
system Programming Software Studio 5000 Logix Designer 100% You use the Studio 5000 Logix Designer® application to configure CompactLogix 5380 controllers.
system AERtronic 2.0 AERtronic 2.0 module 100% AERtronic 2.0 EtherNet-IP Integration Instruction (for Allen Bradley - Rockwell PLC)
system Allen Bradley / Rockwell PLC Allen Bradley / Rockwell PLC 100% Ethernet/IP connection to Allen Bradley/Rockwell PLC MUST be made through the LAN1 port
system Rockwell Studio 5000 / RSLogix 5000 Studio 5000/RSLogix 5000 100% Open Studio 5000/RSLogix 5000
system Product Name PowerXL DM1 Series VFD 100% PowerXL DM1 Series VFD Effective May 2021
system PanelView Plus 7 Performance Terminals PanelView Plus 7 Performance Terminals 100% PanelView Plus 7 Performance Terminals User Manual
system Grundfos Booster System Grundfos Control MPC (CU 35X) 100% Grundfos Control MPC (CU 35X)
system Grundfos Booster System Grundfos DDD (CU 354) 100% Grundfos DDD (CU 354)
system Grundfos Booster System Grundfos Hydro Multi-E model G 100% Grundfos Hydro Multi-E model G
system Grundfos Booster System Grundfos Hydro Multi-E model H, I, J and K 100% Grundfos Hydro Multi-E model H, I, J and K
system Grundfos Booster System Grundfos TPED model H, I, J and K, twin-head pump 100% Grundfos TPED model H, I, J and K, twin-head pump
system Grundfos Booster System Grundfos MAGNA3-D, twin-head pump 100% Grundfos MAGNA3-D, twin-head pump
system product name RFScada 100% The RFScada units have this capability built in, via an industry standard protocol called Modbus
system Modbus RTU Module CIM/CIU 200 Modbus RTU 100% CIM/CIU 200 Modbus RTU
system 3G/4G Cellular Module CIM/CIU 260 3G/4G cellular 100% CIM/CIU 260 3G/4G cellular
system Ethernet Module CIM/CIU 500 Ethernet for Modbus TCP 100% CIM/CIU 500 Ethernet for Modbus TCP
system Grundfos Booster System Grundfos Hydro Multi-B (CU 323) 100% Grundfos Hydro Multi-B (CU 323)
system Grundfos Booster System Grundfos Hydro MPC (CU 35X) 100% Grundfos Hydro MPC (CU 35X)
system Grundfos Control Unit CU 323 100% CU 323 Grundfos Control Unit used in Hydro Multi-B booster systems
system software Data Delivery Devices software 90% PC software supplied allows units to be reconfigured in the field
system FactoryTalk View ME Station FactoryTalk View ME Station 90% FactoryTalk View ME Station
system Software Power Xpert inControl 80% Software Tab: To download Power Xpert inControl and software support