**08:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1765988979961559):**
![[F0A3RGY4S95_pxl_20251217_162909008.jpg]]
![[F0A3RGYQTAB_pxl_20251217_162853320.jpg]]
![[F0A519N5LKS_pxl_20251217_162850029.jpg]]
![[F0A519M5F9N_pxl_20251217_162845746.jpg]]
![[F0A4AHVL8QL_pxl_20251217_162841095.jpg]]
**08:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765989010622649):** damn
**08:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765989016739289):** all remote IO
**08:32 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1765989176045349):** Interesting way to do it.
**08:38 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1765989484852129):** Does it make any sense to you what this second eth card is for? The cable routes to the switch then to the HMI. Why use this card rather than the native port on the processor?
**08:38 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765989528302449):** that i do not know.. unless one NIC for IO.. one nic for HMI and one nic for the network back to scada?
**08:48 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1765990109735269):** Any clue in the program? Not sure if there is any way to assign tags to a port or something
**08:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990179697199):** looking, but not sure it will tell us much.. we can look at the subnets assigned.
**08:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990186124459):** that could tell us the intention for each port
**08:50 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990241483769):** one nic is labeled FlexIO
**08:50 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990247108799):** and the other is labeled HMI
**08:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990264742339):** why dont we just configure the onboard port for SCADA comm
**08:56 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765990569705379):** unless the HMI is on the same subnet as scada then we can just plug into that switch?
**10:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765996057551319):** Did we come up with a game plan?
**10:42 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1765996963129109):** What is the IP of the HMI port?
**10:52 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1765997571640309):** The offline program doesn't show them for some reason
**11:33 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766000002981789):** Ok. I'm back on site. Let me get this terminated and powered up hopefully
**12:31 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766003466967739):** Eth terminated. Waiting for the ok to power the PLC
**12:32 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766003534522619):** Ok. Did we figure out an IP?
**12:32 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766003559529039):** I can maybe bootP it remotely i can try
**12:36 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766003766571499):** Do you have the IP list for the plant network?
**12:36 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766003796730739):** Let me look
**12:43 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004226229969):** ok found it
**12:44 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004287211349):** so probably on the 10.15.20.x network
**12:46 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004389787649):** i think we could stick it at 10.15.20.140
**12:47 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004424036309):**
![[F0A45EMB93P_image.png]]
**12:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766004459399379):** So 140, 141
**12:47 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004478301309):** 141 for the HMI?
**12:48 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766004505336069):** Ya
**12:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004508595869):** copy that
**12:49 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766004565588659):** They have IPs assigned. He's going to send me them. Hopefully we coordinated early on. I can't remember
**12:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004597481829):** :crossed_fingers:
**12:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004701590829):** are they sending now? it would be nice to get a ping on that PLC
**12:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766004708867919):** so i can let loose on the scada tags
**14:03 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766008981119579):** Would it make sense to have the HMI on separate network than scada?
**14:03 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766008989879209):** Addresses are wrong
**14:03 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766009013233629):** But we can set the processor NIC to whatever we want
**14:03 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766009021948419):** @Mason Radke
**14:23 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766010208208699):**
![[F0A462B6M1T_img_20251217_142311.jpg]]
**14:23 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766010229682539):** IP is set
**14:24 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766010276541519):** Ok.