# #laguna — 2025-12-20 **07:22 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766244152798829):** getting things retagged. lotta work to do ![[F0A4MMSSQ59_image.png]] **07:22 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766244161172229):** but making good progress **08:06 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766246794669999):** Have you looked into the issue with train? 3. Digital outputs **08:06 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766246812583809):** no, might need a little more direction **08:07 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766246849860069):** When we try to operate a valve in hand from the HMI nothing happens. There are no outputs from the PLC **08:07 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766246860875979):** And this is true for all valves **08:08 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766246882365769):** ok are you going back onsite today? **08:08 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766246893641339):** Yes, I am driving there now **08:08 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766246896259779):** copy **08:08 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766246911416569):** i'll dig into the HMI, see if i can find what tags theyre tied to **08:09 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766246942174699):** Okay sounds good. It seems like there's some interlock or something that's keeping these valves from operating **08:09 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766246976507609):** ok. **08:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766247613833839):** ![[F0A4MS8HSFM_image.png]] **08:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766247633868879):** so it looks like this HMI status needs to be greater than or equal to 10 **08:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766247654643099):** which is any status other than off **08:22 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766247758317849):** if we want to work on that HMI in any way we will need factorytalk ME somewhere.. we could do it from your laptop. but ideally would be installed somewhere there **08:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248145543589):** Awesome thanks **08:30 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248234646869):** The train won't go into manual. Can you tell what step 2 is? **08:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248244122319):** i was just looking at that **08:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248249695419):** let me see if i can decipher it **08:31 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248289331749):** i think it will stick on step 2 if a shutdown condition exists **08:32 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248323184459):** ![[F0A4MT3CTC3_image.png]] **08:34 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248440318819):** ![[F0A5NJ74G0Y_image.png]] **08:34 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248452324499):** also this rung is waiting for level before moving from step 2 to 3 **08:34 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248463903659):** but the LT signal is either not scaled or not coming in yet **08:35 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248541434489):** Copy **08:35 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248546984859):** Looking now **08:36 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248597344519):** Can you check scaling **08:37 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766248641303919):** Standby **08:39 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248753239949):** rack 2, card 6, channel 2 **08:40 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248823882199):** Raw Value = -1.4231955 **08:40 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248827380699):** scaling 0-20ma **08:41 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766248882493589):** raw scaling on the card is 0-20000 **08:44 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766249051793949):** Can you tell me what imputs the LSH and LSL should be for train 3 **08:44 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249059090889):** standby **08:45 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249149471849):** Lshh = rack 2, card 1, channel 6 **08:46 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249193059639):** Lsll = channel 8 **08:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766249256772289):** Do you see any of those as 1? Also check train 4 **08:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249329331949):** ![[F0A4QSW8G7P_image.png]] **08:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249335400769):** lsh for both trains is a zero **08:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249344966259):** the _in tag is the one tied to the physical input **08:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249375042019):** ![[F0A57814525_image.png]] **08:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766249385105779):** same for LSL. zeros for both trains **09:01 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766250087095169):** Can you tell why we have a high and low alarm on train 3 and not 4 **09:01 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766250101798159):** lemme look **09:08 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766250483521729):** ![[F0A4SAC3W06_image.png]] ![[F0A4UBDRTNW_image.png]] **09:08 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766250494521289):** ok, since both floats are zero it is alarming on both **09:14 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766250854051289):** Copy **09:15 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766250919881179):** Your work here is very helpful **09:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766251061424999):** Alright still unable to put train 3 into manual **09:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766251067946759):** What's next **09:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251073140089):** let me look **09:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251211825169):** can you send me a photo of where on the HMI you are trying to put it in manual? **09:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251216903979):** it will help me find the tag and back track **09:23 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251400415109):** ![[F0A4N1C52E7_image.png]] **09:23 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251421143669):** i think because its in between steps 1 and 9 its trapped in Mode 0 **09:24 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766251446236809):** ![[F0A4Y0P203E_img_20251220_092348.jpg]] **09:24 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251468574179):** ok let me check this **09:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766251629840259):** is there level in the tank? it would help if the levels were working. i got it past the step where it was waiting for level by lowering the setpoint **09:27 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766251649847819):** Yeah let me get that working **09:42 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766252530860179):** Do you have level for 3? **09:43 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766252628738689):** yes i see 42.2 **09:45 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766252744128899):** the setpiont is 83 before it will move out of this step that its trapped in **09:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766252840713389):** What's the setpoint for 4 **09:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766252884630179):** looks like 88 inches **09:48 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766252931577829):** Ok well, let's change that setpoint for 3 temporarily and see if we can move the mode **09:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766252961428319):** ok.. there is a limit somewhere that wont let me drop it below 70 let me track that down **09:51 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766253062744819):** Maybe scaling is off **09:51 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766253072166499):** We have more than 40inches **09:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253094742059):** do we want to verify level/scaling? **09:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253098840729):** or fake it? **09:51 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766253103111269):** Verify **09:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253107087689):** copy **10:01 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253681083479):** im still not sure if the 0ma-20ma is on purpose. **10:01 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253709452059):** but if we can measure the actual level, i can change to 4-20 and see if the numbers make begin to make sense **10:06 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766253961122069):** Copy **10:06 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766253985702909):** Or we set the raw min to what 4ma is **10:06 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766253999741149):** ya **10:09 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254168689689):** 0 to 277 inches **10:10 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254202006229):** i think its set 0-144 in the plc **10:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254344274389):** after changing ot to 0-277 i am seeing 81.2 **10:12 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254357694009):** That's pretty good **10:12 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254366581419):** I'll measure exact **10:13 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254424074799):** But still can't put it in manual **10:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254477015969):** setpoint is 83 **10:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254479599979):** we're not quite there **10:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254480871409):** let me lower it **10:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254521277379):** try now **10:15 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254559464209):** Manual! **10:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254563881189):** boom **10:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254586442449):** Did you scale tank 4 **10:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254593342169):** same scaling? **10:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254643505409):** beginning to notice some programming inconsistencies. **10:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254655720219):** this transmitter uses tags for min max. the other was hard coded **10:18 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254686459459):** Oh boy **10:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254801506669):** i have the scaling set, but the signal isnt coming in yet **10:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254881487019):** whats next? **10:21 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766254899130179):** Tanks 3 is 90.5 inches **10:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254915909329):** ok **10:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766254917110859):** standby **10:25 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255146084179):** Sorry, 82 inches **10:25 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255153928109):** ok **10:26 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255163985329):** It was close **10:26 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255207588429):** do we want to do a zero/span and find how far off the bottom its installed, etc? **10:26 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255216208849):** or if the nubmers make sense, we accept it and move on **10:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255270986499):** do you see the value on the HMI? **10:28 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255295103669):** 81.2 **10:28 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255312430409):** As long as we are close I think we are good **10:28 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255321253419):** I can make it closer to 82.. if its measured 82 on the dot **10:28 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255332202729):** Yeah let's get it close **10:29 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255357200239):** how sthat **10:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255384882449):** 77 for Tank 4 btw **10:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255393264929):** 82 on the dot **10:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255396455859):** For 3 **10:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766255426500729):** still no signal for tank 4 **10:31 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255496172539):** Oh standby **10:39 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766255980326969):** Ok **10:40 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256036202799):** ok and what should the level be? **10:40 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256047574749):** 77 **10:41 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256087120779):** ok do you see it on the HMI? **10:42 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256157775189):** Yes. 77.2 **10:44 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256243656789):** ok.. next? **10:45 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256306101729):** Caustic and hypochlorite valve alarms need to go away. These valves don't exist. Need numbers? **10:45 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256340043189):** hm **10:45 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256352728109):** i would need to update the HMI.. or hard code the tags so they just never alarm **10:46 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256364210619):** since i cant update the HMI let me just try to make them go away in the PLC **10:46 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256368092299):** yes what are the numbers **10:46 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256388959439):** Looking **10:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256473544809):** FV-5560 and FV-5360 **10:52 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256771966159):** did 5560 clear? **10:53 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766256808422969):** Yes **10:54 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766256869869669):** and 5360? **10:56 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766257003078389):** Yes **11:00 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766257250286249):** Need the same for train 4 **11:01 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257275568029):** Om. Have valve numbers? **11:01 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766257287891729):** Same with a 4 at the end **11:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257937093289):** hm.. 5560 doesnt look like its in alarm **11:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257946602939):** should i do the same disable job anyway? **11:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257951137649):** (for train 4) **11:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257961941909):** nevermind **11:12 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766257964671379):** looking at the wrong tag **11:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258087334849):** ok that should do it **11:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258184321689):** Can you check an analog input? **11:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258212300649):** Rack 2 card 6 **11:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258219255619):** Input 15 **11:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258236582739):** I'm getting no current **11:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258312874819):** thats an 8 channel card **11:18 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258337914589):** Oh ch8 **11:19 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258370659079):** 7 **11:19 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258379942749):** yeah. getting essentially zero **11:19 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258387381279):** everything looks ok on this end **11:20 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258402423449):** K **11:20 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258441439229):** Now? **11:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258468100329):** no change **11:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258475519389):** rack 2, card 6, channel 7 **11:21 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258490753049):** Yes **11:26 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258812427539):** All good now. Can you work on the reject pump faults? **11:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258825055869):** yes. **11:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258832178269):** tagnames help me find it quicker if theyre easy **11:27 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258860850939):** Yep **11:27 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258868643969):** P38 **11:28 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766258894303889):** The fault input needs to alarm on 0 not 1 **11:28 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258905232009):** Ok **11:28 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766258920958929):** Keep the requests coming while I'm working on this one **11:35 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766259345145139):** I think we are close **11:36 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766259381074359):** Yeah? I wasn't sure if it was gonna happen today **11:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766260071319009):** Reject pumps? **11:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766260097445669):** Give me about 5 minutes. Standby **11:48 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766260108779679):** Ok no prob **12:01 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766260900718199):** ok **12:02 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766260937182829):** those should both be clear **12:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766261803910829):** Yep **12:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766261814824539):** Excellent **12:24 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262269355299):** Can you see anything in the code that tells the supply pumps what flow to run? **12:24 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262281129409):** pump tagnames? **12:25 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262322651349):** P3801 **12:25 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262339791999):** We are thinking it is not in there. **12:25 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262356911009):** hm **12:26 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262361484059):** im not seeing a P3801 **12:26 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262384572719):** different than P38_3 and P38_4? **12:26 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262394986049):** Correct **12:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262425731519):** can you show me on the HMI? **12:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262429828539):** it will help me identify the tags **12:28 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262504950099):** FIC 7520 ![[F0A5P4B67U0_img_20251220_122758.jpg]] **12:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262543183299):** FI 7620 **12:29 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262583261139):** there is a pump named P3801? that makes a flow rate? its not clear **12:30 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262636415309):** Pump P3801 is in another PLC **12:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262641534089):** oh **12:30 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262654535139):** We need to get this flow setpoint to that other plc **12:31 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262678274989):** i see **12:31 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262678810799):** which PLC? **12:31 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766262719210609):** Standby **12:35 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262934159449):** according to this it seems there has been some confusion around this ![[F0A4RCDFWAH_image.png]] **12:35 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766262942293379):** but we'll fix it **12:37 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766263059004329):** PLC RDS **12:38 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766263083398519):** ok, this may take a minute **12:38 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766263102706109):** No worries **12:46 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766263612658059):** are zeeweed 1 and 2 the old trains? **12:47 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766263620716559):** Yes **12:47 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766263623718639):** ok **13:02 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766264571916819):** there used to be a lot of integration between these two PLCs **13:03 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766264589890739):** but i figure we tackle them as the need/issues present themselves **13:03 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766264593699819):** otherwise it will be overwhelming **13:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265283308319):** ok. I have set up comm between the two PLCs.. and modified the messaging to read in the same value that it was previously.. **13:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265300503069):** but the value that is in that tag in the UF PLC is not the same value you see on the screen there **13:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265308886789):** let me keep investigating **13:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265340279339):** ![[F0A4YFGJL8L_image.png]] **13:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265354096349):** this is what is currently being communicated **13:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265400789179):** that tag isnt tied to anything.. think i should just move the FI-7620 value into that tag to be sent to the RDS plc? **13:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766265476359679):** Do you know how that was getting to the RDS PLC before from Zeeweed? **13:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265490448409):** yes **13:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265492801169):** MSG instructions **13:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265497143519):** from the DH+ gateway **13:20 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766265642272409):** Oh, does it have a DH+ card **13:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265657911629):** i think there was an ethernet gateway **13:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265661369789):** hardwired to the SLC **13:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265668946059):** this msg'd the gateway over ethernet **13:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265690124339):** does that sound right? **13:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265692020349):** thats what it looks like **13:23 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766265823034869):** Yes ok **13:24 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265850811449):** ![[F0A4UTTMAUA_image.png]] **13:24 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265859656189):** the PID in the RDS PLC now has the setpoint that we see on the HMI **13:25 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766265907137779):** Sweet! **13:25 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265908355169):** i only updated the MSG and then moved the FIC 7520 value into the tag it was already reading. which was F201[25] **13:25 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766265941063679):** i had to add the UF plc to the IO tree of the RDS PLC but that went smooth **13:26 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766266019459299):** So glad you are here **13:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766266034342859):** good! and i love this stuff **13:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766266052754769):** even though its like driving a ferrari blind through a tunnel **13:27 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766266067455729):** Lol **13:29 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766266194558649):** Ok, heading back to the plant now **13:37 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766266666921599):** the PID is not ramping up only because of an interlock. ![[F0A4STMQ4G6_image.png]] **13:37 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766266675792699):** the pump isnt ready to run. **13:38 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766266693947399):** maybe its off or something... **13:44 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267087268359):** how are we lookin? i may need to step away for a bit here pretty soon **13:48 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766267317725799):** How late can you work today **13:48 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267330536539):** 12 more minutes? **13:49 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766267355421569):** Ah ok. **13:49 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267373573799):** wish i had more time. but we have dinner reservations **13:50 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766267422521639):** No problem **13:50 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267450423219):** i have time tomorrow but broken up. i have an event from 9-11am pst. **13:51 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267475641579):** but monday i will be available all day again **13:52 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766267545169099):** i am waiting on my friend to finish up a photography gig.. it could run late.. i may have time to knock out one ore two more bugs if you know whats next **14:13 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766268832883749):** ![[F0A57UQ7Q65_pxl_20251220_221222640.jpg]] > **06:52 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766415166264649):** > ![[F0A5WGYDT40_image.png]] > **06:52 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766415175600949):** do think they did this yesterday? > **06:53 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766415183227119):** i'll see if i notice code changes > **06:56 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766415386650489):** I think he put the interlocks on disable or something like that > **06:56 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766415419500359):** ok.. i'll see if i can sort out what they did. i know its early for you there.. take your time > **07:15 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416535049099):** Shouldn't be any code changes except for in the UF PLC. They swapped IO for the two process pumps. > **07:15 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416553213169):** Jerry was able to disable those interlocks on SCADA somehow > **07:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416564166759):** hm.. they're not in bypass. > **07:16 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416582407939):** still investigating > **07:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416624022169):** Yeah it wasn't bypass it was something else he did > **07:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416637105019):** wait > **07:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416638475649):** i just found this > **07:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416639395439):** I didn't watch but I was there when he did it > **07:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416642913029):** > ![[F0A52CTCSR0_image.png]] > **07:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416649610969):** they are in bypass > **07:18 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416696031619):** Ah. Wonder what those other bypass switches do > **07:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416711639029):** > ![[F0A4Z0HR553_image.png]] > **07:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416712986929):** theres also this.. see left and right sides > **07:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416718896309):** im not sure the difference et > **07:18 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416719709629):** yet > **07:19 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416740465659):** Hmmm > **07:19 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416772026399):** I'm sure we will find all sorts of interesting things > **07:19 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416793076619):** this scada has a lot going on > **07:20 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416831033569):** should i try to get these values MSGd over so we can take them out of bypass? what should i focus on first? > **07:20 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416858517229):** Yeah that will be great. That way they can run those pumps > **07:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766416871890719):** perfect thanks > **07:21 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766416883956899):** That k you sir > **07:30 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417459094189):** hm. he did not bypass from scada. still need to figure out what jerry did. if you can remember any details that might help let me know.. otherwise i'll keep digging > **07:35 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766417707255079):** I was sitting there when he did it. It was on SCADA. > **07:35 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417718756689):** hm. ok > **07:35 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417735613179):** oh maye im not logged in! > **07:35 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417736670019):** standby > **07:36 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417774943399):** ok yes, thats all it was.. when im not logged in it acts like the tag isnt linked up.. with a red X > **07:36 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417779527539):** (when i try to toggle > **07:36 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766417786924209):** ok, progress. > **07:43 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766418213294059):** theres quite a bit of unfinished logic on this comm stuff.. in case they thought they paid for it already > **07:50 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766418638892969):** Interesting > **07:53 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766418794425219):** actually i just found some tag descriptions.. they did lay some groundwork for it. > **07:53 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766418809399249):** not as "unfinished" as i originally thought. > **07:53 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766418821371939):** but there is a data type mismatch i cant fix without a download > **07:53 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766418831554949):** unless i copy to a temporary tag.. which is what i'll do > **07:57 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766419068229289):** Download to the RDS PLC is better after noon. **14:14 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766268858667209):** We need to map the call signal **14:14 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766268884774639):** There is an enormous amount of remapping left **14:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766268908394379):** I can prioritize **14:15 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766268921742539):** I know, but I'm referring to the call signal from the UF skid to call the p3800 oumps **14:15 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766268939598649):** Ooh **14:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766268985555379):** Also need valve open signals from UF **14:16 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766268996749699):** If this is too much for today it's ok **14:17 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269022650999):** Yeah that will have to wait **14:17 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766269062010309):** Think you can work on that in the morning before your thing? **14:19 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269144353549):** I can try. **14:20 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766269245493789):** If not it's ok **14:21 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269293973599):** I just want to be prepared my thing. **14:22 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269323129099):** I should have some time but not sure how Mich time I need on either task **14:22 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269359269669):** Did they bump it up from Christmas to tomorrow? **14:27 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269663567969):** Afterwards too I can work on it **14:31 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766269866612819):** We are fine to wait until Monday **14:31 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766269891647629):** OK, cool I’ll let you know how it goes **14:35 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766270119018049):** Thanks Mason **15:03 [Kevin](https://slack.com/archives/C08JS6KDLBD/p1766271790339119):** They will probably be in the program tomorrow morning FYI **15:25 [Mason Radke](https://slack.com/archives/C08JS6KDLBD/p1766273127235779):** K. I won't want to try to be online at the same time

Extracted Entities

TypeKeyValueConfidenceEvidence
site Client Plant Laguna 100% Client: Laguna
system HMI Software FactoryTalk ME 90% if we want to work on that HMI in any way we will need factorytalk ME
File: Clients/Laguna/Plant/slack/2025/12/2025-12-20_laguna.md
Updated: 2026-02-20 02:16:50.624366