# #south-county — 2025-12-12 **08:33 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765557194356359):** on your way? **08:42 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765557751087699):** I'm here **08:43 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765557784437259):** Look at the mcc PLC and see if we have logic for the floats **08:43 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765557798477019):** Please, thank you, and good morning **08:44 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765557873515819):** Copy! Standby **08:45 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765557935989899):** This is for the secondary sludge pumps **08:46 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765558013221299):** P3211 P3212 **08:47 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765558024278419):** code is opening **08:56 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765558598472169):** ok **08:56 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765558604733879):** lets confirm some things **08:56 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765558608090039):** are there 4 floats? **09:05 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559148406229):** ok its coming back to me now **09:05 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559152607279):** i remember adding this logic **09:05 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559155914669):** ![[F0A37H527FG_image.png]] **09:06 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559169574969):** if this is the same system we definately have float control **09:06 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765559181342959):** Correct **09:07 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765559226038299):** Does it seem possible that the pumps are running on the high float? **09:07 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559242543949):** let me look **09:08 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559299174739):** "start" float calls one pump **09:08 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559303238839):** "LSH" calls both **09:09 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765559381525449):** Ok. Standby. Let me finish wrestling this PLC power supply **09:09 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559391214619):** Copy **09:19 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765559941366059):** Ok I'm ready **09:19 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765559967641489):** What state are the floats in now **09:19 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765559985105689):** looking **09:20 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560032357299):** LSH=0 Start=0 Stop=1 LSL=0 **09:21 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560088035299):** Copy **09:22 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560142976999):** Does LSL alarm on 1? **09:24 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560284360569):** standby **09:25 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560332183689):** Pump off now? **09:26 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560378222379):** yes **09:26 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560379192259):** ![[F0A3DAD1H60_image.png]] **09:26 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560408970329):** Copy. Filling **09:26 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560413993669):** no logic tied to LSL **09:27 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560424528529):** but there could be a scada alarm **09:27 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560425865619):** let me look **09:29 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560587364209):** yes, alarms for LSH LSL in scada **09:31 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560665541799):** Copy **09:31 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560707443569):** I think Mike was just confused. He said the pumps were starting on the middle float, which is exactly what they should do **09:32 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765560779560049):** Correct. **09:33 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765560805232889):** How do comms look today **09:37 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561047612099):** there were a couple in the list.. but not like before where every tag would go bad quality at the same time. **09:37 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561070078449):** for the most part its very clean. let me look again **09:38 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561135009919):** hm just one tag did it **09:39 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561185541419):** yeah it looks good other than the one tag that came through **09:39 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561198188129):** i can reach out to support again to see what i can check for that one **09:44 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765561489591699):** Ok. Looks like the secondary sump is fine. **09:45 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561531381269):** good **09:46 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765561587903109):** You go through all the work to put those nice float indicators on the screen and they don't even look at them. Guess it's for us to use as a tool **09:47 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561634354469):** haha **09:47 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765561641350829):** yeah.. well **09:53 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765562012890839):** Anything else on our list? **09:53 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562023660469):** let me look **09:53 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562037976389):** oh **09:54 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562043705079):** we could test the chemical pump auto failover **09:54 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765562072506899):** Ok. Stamdby **10:03 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765562584524809):** They would rather not mess with it today **10:03 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765562598932829):** Anything else **10:05 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562711135579):** Nope. Not that I see **10:08 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1765562884336779):** Alright. I'm outta here **10:09 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562990817619):** Copy that **10:09 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1765562994141939):** Nice work

Extracted Entities

TypeKeyValueConfidenceEvidence
contact person Mason Radke 95% 08:33 Mason Radke
contact person Kevin 95% 08:42 Kevin
site plant name south-county 90% #south-county — 2025-12-12
system PLC system mcc PLC 80% Look at the mcc PLC and see if we have logic for the floats
task check float logic for secondary sludge pumps check float logic for secondary sludge pumps P3211 P3212 90% This is for the secondary sludge pumps P3211 P3212
task test chemical pump auto failover test the chemical pump auto failover 85% we could test the chemical pump auto failover
File: Clients/SSLOCSD/slack/2025/12/2025-12-12_south-county.md
Updated: 2026-02-20 02:20:20.609220