# #tough-smr — 2025-04-22 **09:48 [Kevin](https://slack.com/archives/C08NFJSU753/p1745340501355829):** @andy I plan to be back to SMR on Friday. I need to run shielded cat5 to the transfer booster. I used what I had to make the run to the other gundfos panel. Do you want me to order more and bill you by the foot? **09:53 [andy](https://slack.com/archives/C08NFJSU753/p1745340794050139):** Yeah that's fine. If you can use the Shireen shielded Cat6 outdoor that's my standard. I can buy the whole role if that's not something you can use **09:56 [andy](https://slack.com/archives/C08NFJSU753/p1745340987244639):** SHI-DC-2021 **10:00 [Kevin](https://slack.com/archives/C08NFJSU753/p1745341203981699):** Copy. **10:00 [Kevin](https://slack.com/archives/C08NFJSU753/p1745341224952519):** @Mason Radke are you available on Friday? **10:01 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745341306689119):** I'll let you know. whats the next step out there. I need to test the VPN. **10:10 [andy](https://slack.com/archives/C08NFJSU753/p1745341843491799):** The VPN sucks, this is my first time using it, and I don’t love it. If anybody has a solution, I’m open to it. Siri has been adding periods during dictation. It’s annoying. **11:51 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745347880752459):** weve had good luck with the stridelinx VPN devices from automation direct **13:08 [Kevin](https://slack.com/archives/C08NFJSU753/p1745352497201559):** Yes the Stridelinx VPN has been solid. **13:09 [Kevin](https://slack.com/archives/C08NFJSU753/p1745352571818959):** @Mason Radke the next step is to get the well controls programmed and on SCADA. After that, we need the monitoring from the three Grundfos controllers. **13:11 [andy](https://slack.com/archives/C08NFJSU753/p1745352686480399):** I have a duplex well control program AOI in there that's not tested, but it should be close, I have another AOI for PID Flow control, instantiated for each well, not tested yet. Those AOIs are represented in Ignition from the gear icon pop up **13:12 [andy](https://slack.com/archives/C08NFJSU753/p1745352738212529):** The UI setpoints might not be tied to the well control AOI, they might be old tags, might need to check that. **13:13 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745352818759939):** peace of cake.. hardest part will be finding time to be onsite. **13:14 [andy](https://slack.com/archives/C08NFJSU753/p1745352873202029):** Kevin if you have a stridelinx available swap it out and get Mason remote access? I can order one if you have a link to one you like **13:16 [andy](https://slack.com/archives/C08NFJSU753/p1745352970698199):** https://www.automationdirect.com/adc/shopping/catalog/communications/industrial_iot_solutions/remote_monitoring_-z-_reporting/se-sl3001 **13:21 [Kevin](https://slack.com/archives/C08NFJSU753/p1745353304804599):** I don't have one. @Mason Radke is that the one we've used? **13:22 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745353352238369):** yep! they have a celluar one as well, but we dont need that here. **13:26 [andy](https://slack.com/archives/C08NFJSU753/p1745353577980419):** Ordered. I'll get that to Kevin or job site and get remote access that actually works. **13:26 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745353617166779):** perfect! **13:31 [andy](https://slack.com/archives/C08NFJSU753/p1745353874049439):** I just talked to another customer about upgrading their 15 year old water treatment plant to using the new PAX (4.10 new) objects and a little cleanup. They should get it budgeted for July. Either/And upgrading another SCADA from wonderware to Ignition. Either way, I got fun stuff coming up **13:33 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1745353998680889):** you do have a lot of fun stuff going on! I really want to wrap up these two big projects ive been working on here. then i can make more time **13:38 [andy](https://slack.com/archives/C08NFJSU753/p1745354328865779):** I totally understand and respect it. **13:38 [Kevin](https://slack.com/archives/C08NFJSU753/p1745354337308829):** @andy do you use the connectors from Shireen? **13:39 [andy](https://slack.com/archives/C08NFJSU753/p1745354359903759):** No I use the platinum pass through shielded **13:39 [Kevin](https://slack.com/archives/C08NFJSU753/p1745354374121929):** copy. **13:40 [andy](https://slack.com/archives/C08NFJSU753/p1745354406693749):** https://www.amazon.com/Platinum-Tools-100054C-Clamshell-EZ-RJPRO/dp/B00939KFOU?th=1 **13:42 [andy](https://slack.com/archives/C08NFJSU753/p1745354530269289):** https://www.amazon.com/dp/B000FI2RVC?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4 **13:42 [andy](https://slack.com/archives/C08NFJSU753/p1745354535229049):** https://www.amazon.com/dp/B00HUAYDEM?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4 **13:42 [andy](https://slack.com/archives/C08NFJSU753/p1745354550964629):** I have a spare set of these you should just use unless you want them. They add up **13:43 [Kevin](https://slack.com/archives/C08NFJSU753/p1745354608479859):** I assume you buy the cable through Amazon. How quick can you get it? Ordering from Shireen will cost my $178 for 2 day ship **13:43 [Kevin](https://slack.com/archives/C08NFJSU753/p1745354620687799):** I don't have a Prime account **13:52 [andy](https://slack.com/archives/C08NFJSU753/p1745355123500359):** I actually buy that through Streakwave because of the shipping issue **13:52 [andy](https://slack.com/archives/C08NFJSU753/p1745355147556239):** I would lean towards buying a premade shielded cable and pulling it in for this case if it's close to the needed length **13:52 [andy](https://slack.com/archives/C08NFJSU753/p1745355179066759):** A little coiled up extra isn't the worst thing **13:53 [andy](https://slack.com/archives/C08NFJSU753/p1745355186598949):** If the conduit can handle it **14:06 [Kevin](https://slack.com/archives/C08NFJSU753/p1745355987422569):** Ok I ordered the cable. $25 shipping through Amazon. I'll have it here either Thur or Fri. I'll borrow your tool and a couple connectors **14:09 [Kevin](https://slack.com/archives/C08NFJSU753/p1745356165617359):** BTW, I believe the Cla-Val flow meter is dead. I put 24v to it and nothing on the screen. **14:31 [andy](https://slack.com/archives/C08NFJSU753/p1745357510625279):** uh oh **14:32 [Kevin](https://slack.com/archives/C08NFJSU753/p1745357546503439):** I wonder if it was installed when the vault flooded and maybe the top wasn't screwed down all the way

Extracted Entities

TypeKeyValueConfidenceEvidence
server Amazon connector link 2 https://www.amazon.com/dp/B00HUAYDEM?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4 85% https://www.amazon.com/dp/B00HUAYDEM?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4
server Stridelinx VPN device link https://www.automationdirect.com/adc/shopping/catalog/communications/industrial_iot_solutions/remote_monitoring_-z-_reporting/se-sl3001 85% https://www.automationdirect.com/adc/shopping/catalog/communications/industrial_iot_solutions/remote_monitoring_-z-_reporting/se-sl3001
server Platinum pass through shielded connectors https://www.amazon.com/Platinum-Tools-100054C-Clamshell-EZ-RJPRO/dp/B00939KFOU?th=1 85% https://www.amazon.com/Platinum-Tools-100054C-Clamshell-EZ-RJPRO/dp/B00939KFOU?th=1
server Amazon connector link 1 https://www.amazon.com/dp/B000FI2RVC?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4 85% https://www.amazon.com/dp/B000FI2RVC?ref_=ppx_hzsearch_conn_dt_b_fed_asin_title_4
site SMR SMR 90% I plan to be back to SMR on Friday.
site Well controls well controls 80% the next step is to get the well controls programmed and on SCADA
system Ignition Ignition 95% Those AOIs are represented in Ignition from the gear icon pop up
system Stridelinx VPN Stridelinx VPN 90% weve had good luck with the stridelinx VPN devices from automation direct
system Wonderware Wonderware 80% Either/And upgrading another SCADA from wonderware to Ignition.
system PAX PAX (4.10 new) 80% upgrading their 15 year old water treatment plant to using the new PAX (4.10 new) objects
task Program well controls and monitoring Get well controls programmed and monitoring from three Grundfos controllers 90% the next step is to get the well controls programmed and on SCADA. After that, monitoring from the three Grundfos controllers