# #tough-smr — 2025-05-30 **15:22 [Kevin](https://slack.com/archives/C08NFJSU753/p1748643740670629):** @Mason Radke I just got to SMR **15:22 [Kevin](https://slack.com/archives/C08NFJSU753/p1748643777121599):** Figured I'd wait until it was 95 deg **15:35 [Kevin](https://slack.com/archives/C08NFJSU753/p1748644546035729):** @andy do you want to check with the County to see if they are going to commission the analyzers or are we? They finally have everything plumbed in **15:36 [andy](https://slack.com/archives/C08NFJSU753/p1748644582846689):** We are **15:36 [Kevin](https://slack.com/archives/C08NFJSU753/p1748644609045119):** Copy. Do wr want to do it now? **16:10 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748646615378319):** I’m ready. Let me know where you want to start **16:12 [andy](https://slack.com/archives/C08NFJSU753/p1748646723342109):** Kyle at county said he will check with his team Monday if you haven’t set them up yet. **16:12 [andy](https://slack.com/archives/C08NFJSU753/p1748646728365789):** Just called him **16:13 [Kevin](https://slack.com/archives/C08NFJSU753/p1748646796753959):** @andy I have not. I will standby on setting up the analyzers. **16:13 [Kevin](https://slack.com/archives/C08NFJSU753/p1748646818460449):** @Mason Radke can you see why the wells are in fault? **16:14 [Kevin](https://slack.com/archives/C08NFJSU753/p1748646851597019):** @andy we need another one of these cables ![[F08V56F8ECR_20250530_161224.jpg]] **16:17 [andy](https://slack.com/archives/C08NFJSU753/p1748647050311989):** I have all of them I can give you **16:26 [Kevin](https://slack.com/archives/C08NFJSU753/p1748647611879069):** Copy **16:27 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647668887599):** oh. dont clear well 6 so i can chase it down **16:27 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647673234559):** did you just clear 5? **16:28 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647688637679):** ah, theyr'e both going **16:30 [Kevin](https://slack.com/archives/C08NFJSU753/p1748647837778649):** Sorry **16:30 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647855849509):** its a weird pax thing for sure. just need to figure out what it is. **16:31 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647867249869):** whats next **16:31 [Kevin](https://slack.com/archives/C08NFJSU753/p1748647877465449):** Why are both wells running? **16:31 [Kevin](https://slack.com/archives/C08NFJSU753/p1748647903941039):** And why is W6 only 45 hz **16:31 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647903973229):** let me look.. **16:32 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647922619799):** w6 is only 45hz because it hasnt reached its flow setpoint to release to PID control **16:32 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647934917149):** the threshold needs to be lowered. **16:32 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748647960310299):** ![[F08UQDLHRK7_image.png]] **16:33 [Kevin](https://slack.com/archives/C08NFJSU753/p1748647986154119):** Copy **16:33 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648014069479):** ![[F08UU0J9KT4_img_20250530_163313.jpg]] **16:36 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648194136359):** lag call must have been latched while they were faulted.. and after you cleared they both started.. **16:36 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648209499889):** lag pump will stop at setpoint.. or we can simulate tank level for a second to test the lag stop **16:37 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648228543509):** Ok we can let it do it's thing **16:38 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648318184589):** Let's figure out booster status. **16:38 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648322430459):** sounds good **16:39 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648351792889):** I have p3 on at 900 rpm **16:39 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648362214629):** In hand on vfd **16:39 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648367917119):** ok, standby **16:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648542722829):** hm, i dont have a 1 for running status but i do see a speed value of 4173 **16:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648562429599):** i can infer running status if speed >0 **16:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648564656309):** if we have to **16:43 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648627504369):** It doesn't show running on the CU352 either **16:44 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648643512189):** Gonna try auto **16:45 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648703503109):** How about now? **16:45 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648717513119):** i see pump1 and pump3 running **16:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648782967219):** linking up some things to the pax object **16:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748648790858459):** we need to figure out the scaling on this speed value **16:46 [Kevin](https://slack.com/archives/C08NFJSU753/p1748648802587569):** Copy **16:57 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649478780729):** ok.. its blue.. some pax stuff to figure out on why it doesnt think its running **16:58 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649486503919):** what is the actual speed of the pump? **16:58 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649499840609):** 28pct **16:58 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649525062699):** Now 1247rpm **16:58 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649528775739):** Set to hand **16:59 [andy](https://slack.com/archives/C08NFJSU753/p1748649553750309):** Blue is starting, (run command but no feedback) **16:59 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649576152079):** yeah. but im feeding it the run signal... it could also be stopping.. (running but no run cmd) **17:01 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649660134689):** I have it at 10pct **17:01 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649679887019):** fixed? **17:01 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649683910129):** it should stay there/ **17:01 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649713737569):** Fixed. But min speed is 900rpm so thats where it's at now **17:02 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649742924209):** are you able to run it 100% for a short period of rtime? **17:02 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649749291859):** Yes **17:02 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649761722799):** that will be helpful.. lets see what that raw value is **17:02 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649771260209):** Here goes **17:03 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649798317789):** 50pct 1800rpm **17:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649814992609):** ok! well that makes sense kinda.. i have 5000 **17:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649817487789):** that could be 50% **17:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649829135299):** 5984 now **17:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649837806019):** 8000 **17:04 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649854799419):** 100 **17:04 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649863306029):** ok, its 10000 **17:04 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649871382889):** so i think we can assume the feedback is %*100 **17:04 [Kevin](https://slack.com/archives/C08NFJSU753/p1748649894736639):** 50 **17:05 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649931886729):** this isnt making sense from the faceplate **17:05 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649958562829):** ![[F08ULA8MBGB_image.png]] **17:05 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649959964549):** 5000 going into the object **17:06 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649977648799):** ![[F08UDF3SSFR_image.png]] **17:06 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649979381239):** 25000 showing on the faceplate **17:06 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649992415619):** standby. **17:06 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748649995072229):** investigating **17:19 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748650756722389):** boom **17:19 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748650759386849):** ![[F08V5AB3XQ9_image.png]] **17:19 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748650777559759):** i updated the UDT to grab the speed feedback input and updated the faceplate to display the actual input **17:19 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748650783001739):** now things are making sense **17:20 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748650805640729):** let me work on the stopping status now **17:41 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652082129579):** ok. **17:41 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652084138889):** got her sorted out **17:41 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652088848059):** ![[F08ULC6EY3D_image.png]] **17:41 [Kevin](https://slack.com/archives/C08NFJSU753/p1748652107130009):** Nice! **17:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652129633879):** i'll work on updating the other 2 pumps **17:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652137313729):** let me know whats next after that.. **17:42 [Kevin](https://slack.com/archives/C08NFJSU753/p1748652152584799):** Other 5 pumps **17:42 [Kevin](https://slack.com/archives/C08NFJSU753/p1748652161819999):** 4 boosters 2 transfers **17:43 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652190422889):** can you switch to booster pump 1? **17:43 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652196408389):** at whatever speed you want **17:44 [Kevin](https://slack.com/archives/C08NFJSU753/p1748652264866069):** Running **17:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652504215379):** ![[F08ULCJL57V_image.png]] **17:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652505234259):** pump 1 **17:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652510157109):** does the speed look correct? **17:52 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652727685009):** can you switch to pump 2 after you confirm the speed looks good **17:55 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748652949275749):** well 6 is faulted.. im checking the fault. now **17:58 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653131972459):** heatsink overtemp **17:58 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653139212739):** probably because its hot as balls out there? **17:59 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653148440679):** Copy. P1 is good **17:59 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653153937039):** Yeah probably **17:59 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653156573669):** P2 is ready to test **17:59 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653162743629):** P2 running **17:59 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653184319819):** whats the discharge pressure? **18:00 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653222601039):** 77 **18:00 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653257344459):** Running up to W6 **18:01 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653264605539):** i can reset it from here **18:01 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653270028769):** but maybe there is a thermostat that can be adjusted? **18:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653426295409):** ![[F08UDJ5TKJT_image.png]] **18:03 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653429578189):** got system pressure linked up and scaled **18:05 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653517531549):** The cooling fans aren't running on the W6 vfd @andy **18:09 [Kevin](https://slack.com/archives/C08NFJSU753/p1748653759389919):** Stupid drives show you everything except the heatsink temp **18:09 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748653772987409):** i might be able to see it **18:14 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654044725159):** im not seeing it.. probably because its a PF70 **18:14 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654060519179):** Was that POS 70? **18:14 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654080364379):** i think so yes. **18:15 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654107131559):** Booster 2 is at 30hz **18:15 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654118194489):** Only shows 19.85 **18:15 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654130489399):** Better **18:15 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654134337919):** yes. **18:15 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654135054159):** fixed **18:16 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654164250489):** can we run the high flow? **18:16 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654190544549):** No. It makes a terrible noise **18:16 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654206254089):** ok, ill make the same logic and scada changes. **18:16 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654211268499):** it should be good **18:17 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654225574389):** We can run transfer pumps at low speed **18:17 [Kevin](https://slack.com/archives/C08NFJSU753/p1748654256001549):** If you are ready for those **18:17 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654262895169):** just a minute **18:26 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654802342639):** ok transfer pump 1 is ready **18:26 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654808155059):** i also scaled the flow setpoint properly on scada **18:26 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654814241669):** wait.. **18:26 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654817270169):** no i didnt **18:27 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654839075039):** thats going to take some figuring out **18:27 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748654847871549):** but pump1 is ready for status testing **18:31 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655115388039):** K here goes **18:32 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655153635189):** without the system enable bit, we dont get run status back **18:33 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655190822069):** i can fake it.. if we have feedback we can assume its running **18:33 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655204310789):** K. You see speed? **18:33 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655206997009):** yes **18:33 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655218557249):** ![[F08UU7GTTMG_image.png]] **18:33 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655236238239):** should i work on the run status modification? **18:34 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655242039939):** once its in auto we will get the actual run status **18:34 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655275660929):** No it's ok **18:34 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655282695559):** 50pct? **18:34 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655299178829):** yes sir **18:35 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655301006149):** ![[F08UMDT8REJ_image.png]] **18:35 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655324299519):** Cool **18:40 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655608394909):** Test p2? **18:40 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655611318109):** ready **18:40 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655656525549):** 50pct **18:41 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655670999829):** copy that **18:41 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655671711719):** ![[F0902TPPF32_image.png]] **18:42 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655732230669):** Fault status from CU? **18:42 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655742276089):** can we make a fault status? **18:42 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655774218779):** ![[F08UDL0HSPR_img_20250530_184236.jpg]] **18:43 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655798373969):** is it clearable? (for testing? let me locate the bit first) **18:43 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655807113249):** Yes **18:45 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655920197439):** hm.. go ahead and clear it **18:45 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655932874349):** Clear **18:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655976624489):** which system are we looking at? **18:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655980228899):** transfer or booster **18:46 [Kevin](https://slack.com/archives/C08NFJSU753/p1748655983677069):** Transfer **18:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655988209219):** oh.. ok.. lets try again **18:46 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748655989716769):** can you fault it **18:46 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656008419239):** Fault **18:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656089639619):** is this comm fault for pump1? **18:48 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656093943329):** Yep **18:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656115319069):** ok.. where do we want to see this? **18:48 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656134122579):** drive fault on the faceplate? ![[F08UU86RBLJ_image.png]] **18:50 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656210779489):** 10 min till beer thirty **18:50 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656245783789):** Is this going to be a generic fault for the whole system? **18:51 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656272287899):** i dont know. thats my question as well **18:51 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656287888959):** Let's try p2 fault? **18:51 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656289242419):** that particular fault came in on pump 1 **18:51 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656312727369):** I can cause a general fault **18:52 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656334050579):** K general fault **18:52 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656341289479):** Or system fault maybe **18:53 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656394852969):** there is an alarm code ![[F08UMENT63Y_image.png]] **18:53 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656413071439):** ![[F08UDLFSPPZ_image.png]] **18:53 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656417156739):** and it shows both pumps in alarm **18:54 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656456341609):** Ok so we have an alarm for each pump, and a system alarm. **18:54 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656474864319):** So set the pump alarms on the pump faceplates **18:54 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656489253829):** how do we identify the system alarm? **18:54 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656497202649):** And create a Pdin? **18:55 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656527652369):** well. i think we'll feed the pump alarm statuses into the VSD object directly **18:55 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656538106279):** Yes **18:55 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656546565659):** not sure what to do with the alarm code. **18:56 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656560539649):** we'll have to map certain values to statuses? **18:56 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656580791529):** Maybe just if>0=alarm? **18:56 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656617364089):** we'll have to verify thats the case **18:56 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748656619399379):** but we could do that **18:57 [Kevin](https://slack.com/archives/C08NFJSU753/p1748656636387919):** All faults clear **19:05 [Kevin](https://slack.com/archives/C08NFJSU753/p1748657137796719):** I'm heading home **19:05 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748657152858859):** ok.. im just linking up that alarm bit to the pax objects **19:05 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748657156884099):** then i'll close out too **19:06 [Kevin](https://slack.com/archives/C08NFJSU753/p1748657181940019):** Thanks for your work today **19:06 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748657197003819):** no problem! we made some more progress.. we're getting there **19:06 [Kevin](https://slack.com/archives/C08NFJSU753/p1748657212899929):** It's real close!

Extracted Entities

TypeKeyValueConfidenceEvidence
contact Kevin Kevin 95% **15:22 [Kevin](https://slack.com/archives/C08NFJSU753/p1748643740670629):**
contact Mason Radke Mason Radke 95% **16:10 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1748646615378319):**
contact andy andy 90% **15:36 [andy](https://slack.com/archives/C08NFJSU753/p1748644582846689):**
site SMR Plant SMR 90% @Mason Radke I just got to SMR
task Update pump UDT and faceplate Update UDT to grab speed feedback input and update faceplate display 90% i updated the UDT to grab the speed feedback input and updated the faceplate
task Test booster pumps Test and confirm speed and running status of booster pumps 1 and 2 85% can you switch to booster pump 1? at whatever speed you want
task Fix well 6 fault Investigate and fix fault on well 6 (heatsink overtemp) 85% well 6 is faulted.. im checking the fault. now heatsink overtemp
task Commission analyzers Determine if County or Tough will commission analyzers 80% check with the County to see if they are going to commission the analyzers