# #tough-smr — 2025-05-09 **08:22 [Kevin](https://slack.com/archives/C08NFJSU753/p1746804168060809):** @Mason Radke I think we can take a stab at this. Look in the program to see if there are already motor aois for the boosters. Add them if not. Build a scada page for the distribution boosters and the transfer boosters. Make sure both wells are on the Well screen. **08:30 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1746804654739199):** Sounds good. **08:33 [andy](https://slack.com/archives/C08NFJSU753/p1746804832097669):** The VSD objects are there for boosters, are the transfer pumps starters or VFDs? **08:42 [Kevin](https://slack.com/archives/C08NFJSU753/p1746805334525499):** Starters **08:49 [andy](https://slack.com/archives/C08NFJSU753/p1746805795862919):** There is no booster page, booster/transfer page probably makes sense. The "well 4" labels are from the previous project they are copied from, those pages just are convenient containers for analog or discrete objects for the system. I've been creating instances for all IO 0-7 for example, even if they aren't currently used, they are organized in their IO order for troubleshooting and testing ease **08:52 [andy](https://slack.com/archives/C08NFJSU753/p1746805974694839):** I added some notes into the SMR Controls doc for Ignition and the plant pax object configurations: https://docs.google.com/document/d/1MXYwKV8f2uzhH6KQCulw-kEItgv1kc7x0DKvKwFaXpc/edit?usp=sharing [[F08RGAY8U7Q_smr_controls]] **09:13 [andy](https://slack.com/archives/C08NFJSU753/p1746807229135239):** Transfer and Booster pumps are monitor only, we are providing a pressure setpoint to the booster skid if it allows **09:14 [andy](https://slack.com/archives/C08NFJSU753/p1746807260882669):** the doc shows which instances are for what pumps **10:15 [Kevin](https://slack.com/archives/C08NFJSU753/p1746810915339679):** I think we need to provide start/stop and flow setpoint to the transfer pumps? > **11:45 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1746902715969869):** should the start/stop be treated more like an enable/disable? since the grundfos controller will be starting and stopping as pressure demands (when PLC start is enabled) > **12:37 [Kevin](https://slack.com/archives/C08NFJSU753/p1746905838111879):** yes > **12:37 [Kevin](https://slack.com/archives/C08NFJSU753/p1746905850225279):** we will feed a setpoint to the grundfos, then enable/disable it

Extracted Entities

TypeKeyValueConfidenceEvidence
contact person name Kevin 100% 08:22 [Kevin]: @Mason Radke I think we can take a stab at this.
contact person name Mason Radke 100% 08:30 [Mason Radke]: Sounds good.
contact person name andy 100% 08:33 [andy]: The VSD objects are there for boosters, are the transfer pumps starters or VFDs?
site plant name SMR 100% #tough-smr — 2025-05-09
system product name Ignition 100% 08:52 [andy]: I added some notes into the SMR Controls doc for Ignition and the plant pax object configurations
File: Clients/Tough/SMR/slack/2025/05/2025-05-09_tough-smr.md