# #tough-smr — 2025-05-17 **08:37 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747496228222569):** I’ll wait for that one. **12:13 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747509206519729):** transfer pump controller will be maintaining flow or pressure? **12:14 [Kevin](https://slack.com/archives/C08NFJSU753/p1747509287125059):** Flow **13:12 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747512771705859):** :wrench: *SCADA Update Checklist* • Fix sparkline on tank object ◦ Simply added a static sparkline object on the tank. Let me know if i should spend the time on updating the object to work dynamically with the passed tagname. • Correct Claval flow rate label (currently says “Well 6”) ◦ Updated • Remove scroll bars from analog objects on Well screen ◦ I think this has been fixed.. i need logmein access to confirm for sure. the resultion is slightly different on my machine.: • Add flow rate and setpoint display for transfer pumps ◦ Added • Disable HOA on boosters and transfer pumps ◦ Added a new parameter for the pump object that gets passed to the faceplate and its child objects called ShowControls.. if ShowControls=false it will hide HOA, manual speed command and anything else we decide to hide. • Fix ‘Close’ button on pump faceplate (currently not functioning) ◦ Fixed • Consider adding an alarm bar (pending @andy’s approval) ◦ Need to see how much room we have on the panel PC display. we may need to move things around to make room for an alarm bar. • Add setpoint (SP) for the Claval valve ◦ Updated • Check if there is a Claval valve object available ◦ Waiting on valve faceplate tempalte from Andy **13:13 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747512786661929):** ready for the next round of updates/suggestions/changes/fixes **13:16 [Kevin](https://slack.com/archives/C08NFJSU753/p1747512964573259):** Fabulous! The other thing i remembered is we need to display the flow totalizers. Also, do we have a totalizer from the claval meter? If not we need to make one in the plc **13:16 [Kevin](https://slack.com/archives/C08NFJSU753/p1747513005453509):** I think runtime also for each pump **13:17 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747513023818459):** runtime is taken care of with the PAX object and the faceplates already **13:17 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747513045588159):** ![[F08TJKPB3T2_image.png]] **13:17 [Kevin](https://slack.com/archives/C08NFJSU753/p1747513050854549):** Copy! **13:18 [Kevin](https://slack.com/archives/C08NFJSU753/p1747513098434219):** I'll just go back to digging holes ![[F08TJKPRZ08_20250517_121533.jpg]] **13:18 [andy](https://slack.com/archives/C08NFJSU753/p1747513112809679):** I usually don’t do alarm bar, I show indicator on header but they have to open status or history **13:19 [andy](https://slack.com/archives/C08NFJSU753/p1747513140508419):** Everything I’m reading looks great I can’t view right now but Kevin’s notes sound right on my vision **13:19 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747513173327119):** good! yeah let me know when you can take a look and we can get it dialed in even more.. im just throwing stuff together to get us a starting point **13:20 [Kevin](https://slack.com/archives/C08NFJSU753/p1747513224610439):** I think it's looking real.good. **13:22 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747513342478969):** we'll have to decide which status bits from the grundfos to use for Fault and Off status symbols. **13:22 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747513356366079):** but easy to do once we start playing with the system and doing our final testing **13:50 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747515021968129):** i think im going to feed the Enable status into ScadaAuto. so when the skid is enabled, there will be no "OFF" icon.. and when its disabled, the pumps will show OFF with the red O.. there is no hand so no need to link anything up there **14:15 [andy](https://slack.com/archives/C08NFJSU753/p1747516504686729):** I jumped on logmein real quick and I love how it’s coming together! I’m stoked guys **14:15 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747516514273239):** sweet!! **14:21 [andy](https://slack.com/archives/C08NFJSU753/p1747516900113599):** A guy could get used to this… I think we can all make a few bucks doing this too. **14:21 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747516911308909):** lets do that. **14:21 [Mason Radke](https://slack.com/archives/C08NFJSU753/p1747516916473589):** i like the sound of that

Extracted Entities

TypeKeyValueConfidenceEvidence
contact Person Mason Radke 100% 08:37 [Mason Radke]
contact Person Kevin 100% 12:14 [Kevin]
contact Person andy 100% 13:18 [andy]
site Client Name Tough 100% Client: Tough
system SCADA System ScadaAuto 80% feed the Enable status into ScadaAuto
task SCADA Update Checklist Fix sparkline on tank object, Correct Claval flow rate label, Remove scroll bars, Add flow rate and setpoint display, Disable HOA on pumps, Fix Close button, Consider alarm bar, Add setpoint for Claval valve, Check Claval valve object 90% SCADA Update Checklist • Fix sparkline on tank object • Correct Claval flow rate label ...
File: Clients/Tough/SMR/slack/2025/05/2025-05-17_tough-smr.md
Updated: 2026-02-20 02:20:25.845397