# #ccsd-water-ignition — 2025-08-18 **08:00 [andy](https://slack.com/archives/C08TVA84PD4/p1755529253636469):** Leimert looks good **08:24 [andy](https://slack.com/archives/C08TVA84PD4/p1755530673545059):** I attached IO schedule of the Leimert PLC (it has some errors I attempt to explain here) I'm looking at the wiring diagram from the booster station, we have a "Low Pressure Override Switch" (Closed 25 PSI and Open 35 PSI) that triggers a low pressure PLC discrete input. On the IO screenshots I have to assume that [02]-0 (di_lowPressureOverride_C) is that input. I also have a "Low Tank Level Switch" that engages the Low Level Cutout relay and PLC input[02]-1 (di_lowPressureOverride_D). I would like that to go to a dedicated PAX P_DIn object. We have "Booster Pump Fail" and "Motor Hot Relay" for each of the 4 motors which will just be failure inputs to the motor object, not separate objects. *These are not currently wired into the PLC and are not represented in the IO schedule.* *This will come in a future upgrade, so please allow for these signals as you develop.* ![[F09ATNYTGMB_screenhunter_486__01_.png]] ![[F09AHF4MX9D_screenhunter_487__01_.png]] **08:25 [andy](https://slack.com/archives/C08TVA84PD4/p1755530737485189):** ![[F09ATSUHVGV_img_5561.jpg]] ![[F09AVNZMSTU_img_0115.jpg]] ![[F09ATSTHLBF_img_0118.jpg]] ![[F09ATSTV2H3_img_0117.jpg]] **08:27 [andy](https://slack.com/archives/C08TVA84PD4/p1755530821622609):** I put together Leimert booster in an emergency once the tesco controller failed, it's not my best work, and it was from 2015. I apologize for the confusion from the discrepancies **08:28 [andy](https://slack.com/archives/C08TVA84PD4/p1755530914145959):** Very happy with the progress, and I figured out how to turn off notifications until Monday 7AM, so I wasn't bothered. Let me know if you have outstanding questions, I should be pretty available. **09:26 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1755534381146479):** Excellent! Hoping to have some hours today as well. Will keep you posted **16:34 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1755560055466819):** @andy stuart and fiscallini are both on 204. do we want to keep those together or break them apart into two separate pages **16:52 [andy](https://slack.com/archives/C08TVA84PD4/p1755561165786239):** I actually want them conbimed as they are **16:53 [andy](https://slack.com/archives/C08TVA84PD4/p1755561201704559):** I’ve had users get confused with the Stewart boosters, not boosting to Stewart having them all on the same page eliminates that confusion **16:53 [andy](https://slack.com/archives/C08TVA84PD4/p1755561209584329):** And Kevin set it up that way so it worked out **16:56 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1755561376018829):** sounds good **17:08 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1755562132588339):** did you happen to make the little IO lists for fiscallini? i dont see them on that page. I could go from the P&ID, but i dont believe they are complete **18:02 [andy](https://slack.com/archives/C08TVA84PD4/p1755565326106459):** I thought I made them for every page, they are copy pastes from a spreadsheet, you shouldn’t have to go off the PID ever unless that’s helpful **18:02 [andy](https://slack.com/archives/C08TVA84PD4/p1755565335924049):** Make sure you are looking for the large view **18:02 [andy](https://slack.com/archives/C08TVA84PD4/p1755565361754139):** I already did that work, I don’t it done twice if we can avoid it lol **18:03 [andy](https://slack.com/archives/C08TVA84PD4/p1755565392681049):** There is a spreadsheet that all of those sheet sheets come from and I thought I gave you access to it. I linked to it from the project document. **19:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1755568891087219):** i did look on the large view. i'll look the the google drive

Extracted Entities

TypeKeyValueConfidenceEvidence
site Leimert Booster Station Leimert 90% "Leimert looks good" and "Leimert booster in an emergency once the tesco controller failed"
system PLC Controller tesco controller 80% "Leimert booster in an emergency once the tesco controller failed"
File: Clients/Tough/CCSD/slack/2025/08/2025-08-18_ccsd-water-ignition.md
Updated: 2026-02-20 02:20:27.763366