# #ccsd-water-ignition — 2025-12-17
**06:10 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765980641051459):**
![[F0A49CFCRRS_image.png]]
![[F0A43PESRT8_image.png]]
**06:11 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765980669629109):** great news! SSWF W2 had enough active DIs to confidentially map All IO from all slots!
**06:11 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765980683758989):** Slots 0-8
**06:24 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765981441770499):**
![[F0A5078D2M6_image.png]]
**06:25 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765981551593779):**
![[F0A3QF578J3_image.png]]
> **16:14 [andy](https://slack.com/archives/C08TVA84PD4/p1766016886671849):** target is 0, the input is not in fault
> **16:39 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1766018363086949):** Can that be handled by the AOI? Can the target be flipped by a cfg bit? I can bnot the input. Just curious
> **16:40 [andy](https://slack.com/archives/C08TVA84PD4/p1766018411883989):** absolutely its the input right there, just making you aware of that, to match the incoming value unless it's actually in alarm
> **16:40 [andy](https://slack.com/archives/C08TVA84PD4/p1766018427460549):** 3rd one
**06:27 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765981629434499):**
![[F0A43T5R0F8_image.png]]
**06:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765981715728029):**
![[F0A3ZHBNM27_image.png]]
**06:29 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765981775324389):**
![[F0A3ZHM78N7_image.png]]
**06:39 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982391089019):**
![[F0A50B7NLSU_image.png]]
> **06:40 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982431570079):** I have a question on the motor IO. there is IO for the well being in auto, but no input in the AOI for inp_auto - how do you like to handle that?
> **06:41 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982463022229):** also i need to experiment and test writing to DO's. i need a separate modbus message for write commands.. it on my to -do list
> **16:20 [andy](https://slack.com/archives/C08TVA84PD4/p1766017211260209):** inp_auto is handled by the inlk and permissive looking like this:
> ![[F0A4A17RV98_image.png]]
> **16:21 [andy](https://slack.com/archives/C08TVA84PD4/p1766017265518429):** you have to configure the OK states for both inkl and perm
Note Perm goes to Perm01 not 00
> ![[F0A4DJT43PE_image.png]]
> ![[F0A46J4BJBX_image.png]]
**06:45 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982740270129):**
![[F0A3QKXFZ8X_image.png]]
**06:46 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982818308459):**
![[F0A3ZMUL4GK_image.png]]
**06:49 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765982981471729):**
![[F0A3ZNFLFRR_image.png]]
**06:51 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765983074797839):**
![[F0A49N4QRD2_image.png]]
**06:52 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765983173761989):**
![[F0A4650H2E6_image.png]]
**06:54 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765983269497659):** all SSWF W2 IO has been mapped and linked to objects
**06:54 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765983285763399):** other than the auto input which we need to discuss (i started a thread)
**06:54 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765983298608759):** and then setting up and testing the modbus write messages for the pump start command
**08:42 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765989758415099):** @andy something happend to the prosoft.. .i can no longer ping it, or connect to it to modify its configuration..
**08:42 [andy](https://slack.com/archives/C08TVA84PD4/p1765989772701299):** wtf
**08:43 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765989791897019):** yeah, not helpful. i feel like i was close to getting the write commands to work
**08:43 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765989823403329):** the reboot during the last configuration change must have hung it up somehow...
**08:44 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765989863130399):** hopefully just a power cycle and not a factory reset / IP assignment again... (fortunately i have the config saved)
**08:49 [andy](https://slack.com/archives/C08TVA84PD4/p1765990184838159):** ok i'll be on site this afternoon
**08:49 [andy](https://slack.com/archives/C08TVA84PD4/p1765990189831479):** i can power cycle
**08:49 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1765990193662279):** sounds good
**16:24 [andy](https://slack.com/archives/C08TVA84PD4/p1766017459846079):** Good thing I reread this, I'm going to power cycle the device, i totally forgot until now, testing auto functions of SST, RAS WAS 2
**16:24 [andy](https://slack.com/archives/C08TVA84PD4/p1766017491174159):** So far so good, only minor tweaks, i have to reinstantiate the WAS PID, but at least i remembered in 5 seconds not hours
**16:31 [andy](https://slack.com/archives/C08TVA84PD4/p1766017904827199):** Prosoft is running on PLC now
**16:36 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1766018182501659):** Ok good!
**16:36 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1766018217758179):** Sounds like it's going well