# #rancho-ynecita — 2025-10-29 **09:06 [Kevin](https://slack.com/archives/C09D358F91R/p1761754009544599):** @Mason Radke there is a folder in Box named Rancho Ynecita. Folder "Design" In there is a google doc "Rancho Ynecita SCADA Control Narrative" > **09:16 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754591071549):** i dont have a design folder in there > **09:16 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754605961469):** > ![[F09P0RSUEK1_image.png]] **09:07 [Kevin](https://slack.com/archives/C09D358F91R/p1761754029308009):** There is information in the begining of that doc to access the PC **09:07 [Kevin](https://slack.com/archives/C09D358F91R/p1761754048596479):** I was planning on programming this myself back when you were tied up, but I didn't get far **09:07 [Kevin](https://slack.com/archives/C09D358F91R/p1761754070378199):** I was going a bit overboard possibly in the narrative. I started a PLC program. **09:08 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754082321199):** PLC is installed? and we're programming from a PC onsite there? **09:08 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754094367549):** i think overboard on the narrative is better than not enough **09:08 [Kevin](https://slack.com/archives/C09D358F91R/p1761754096366799):** PLC and PC are in the shop **09:08 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754104563669):** ah, gotcha **09:09 [Kevin](https://slack.com/archives/C09D358F91R/p1761754152349669):** I created a couple UDTs, and based the narrative I wrote around that. **09:09 [Mason Radke](https://slack.com/archives/C09D358F91R/p1761754158297939):** do you have to share the folder with me? **09:09 [Kevin](https://slack.com/archives/C09D358F91R/p1761754168198209):** Possibly. Standby **09:11 [Kevin](https://slack.com/archives/C09D358F91R/p1761754317282259):** shared to your gmail **09:13 [Kevin](https://slack.com/archives/C09D358F91R/p1761754388279309):** Feel free to redo the UDT's ,or scratch the whole program. I didnt' get far. But the UDT shows the data I'm interested in passing to and from SCADA. **09:13 [Kevin](https://slack.com/archives/C09D358F91R/p1761754397782269):** PLC software is installed on the PC **09:14 [Kevin](https://slack.com/archives/C09D358F91R/p1761754452385369):** here is some background: **09:15 [Kevin](https://slack.com/archives/C09D358F91R/p1761754518485879):** there currently is a FRM DaqFactory system with RF SCADA boards there are three remote sites (two wells, one tank) **09:15 [Kevin](https://slack.com/archives/C09D358F91R/p1761754543013729):** our new plc will be the data concentrator and the system controller (logic) **09:16 [Kevin](https://slack.com/archives/C09D358F91R/p1761754586549679):** the plc will communicated with the RFScada boards. I plan to figure this out in the field, so we will link IO later

Extracted Entities

TypeKeyValueConfidenceEvidence
site Client Name Rancho-Ynecita 100% Client: Rancho-Ynecita
system SCADA System FRM DaqFactory 90% there currently is a FRM DaqFactory system with RF SCADA boards
system PLC Software PLC software 80% PLC software is installed on the PC
File: Clients/Rancho-Ynecita/slack/2025/10/2025-10-29_rancho-ynecita.md
Updated: 2026-02-20 02:20:28.132657