# #buellton — 2026-02-02
**08:41 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770050460750839):**
![[F0ACG19DJTC_image.png]]
**08:41 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770050497387659):** running an android emulator to test it
**08:41 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770050508073469):** i called Joe, I will work with him on testing..
**08:42 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770050526882049):** he asked for alarms to be on there.. since those arent coming from the PLC and not in kepware, im not sure yet how im going to do that.
**09:19 [Kevin](https://slack.com/archives/C091185E1JN/p1770052756356389):** I don't think they need alarms on mobile if they have it on Signl4?
**09:19 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052770459949):** thats what i thought too.. but he asked for it.
**09:19 [Kevin](https://slack.com/archives/C091185E1JN/p1770052780942669):** They need a way to acknowldege alarms
**09:19 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052784645159):** i have a plan that could work very well.
**09:19 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052796351349):** but will take some time to figure out
**09:20 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052807645839):** could they ack from mobile before?
**09:21 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052886867759):** what are your thoughts? if things go smoothly this might not take too long.
**09:21 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052897585339):** but i will have to look into the acknowledge piece
**09:23 [Kevin](https://slack.com/archives/C091185E1JN/p1770052983172409):** yes they are able to ack alarms from mobile scada.
**09:23 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770052997291109):** oof. ok.
**09:26 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053169526649):** well this looks theoretically possible.. shall i give it a go?
**09:26 [Kevin](https://slack.com/archives/C091185E1JN/p1770053176973439):** yes
**09:26 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053186367729):** copy that.
**09:27 [Kevin](https://slack.com/archives/C091185E1JN/p1770053251014649):** I'm willing to change the alarms to generate from the PLCs if you think that is better
**09:28 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053294673919):** it would be a lot easier on my end for this mobile app.. but also a lot more work on the scada end, and plc programming.
**09:28 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053304865479):** let me give this Geoscada solution a go first?
**09:28 [Kevin](https://slack.com/archives/C091185E1JN/p1770053311292899):** ya
**09:28 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053337484229):**
![[F0ACGCZE76E_image.png]]
**09:29 [Kevin](https://slack.com/archives/C091185E1JN/p1770053393376979):** that looks promising. not sure if it is related but there are "methods" in geo
**09:30 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053437502319):** i have to use a system call action. which runs a script which will push data to an HTTP endpoint in node-red which will relay to thingsboard
**09:31 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053471609129):** its not complicated.. but its complicated.
**09:31 [Kevin](https://slack.com/archives/C091185E1JN/p1770053477031259):** lol
**09:32 [Kevin](https://slack.com/archives/C091185E1JN/p1770053522486579):** this will be slick if you can make it work
**09:32 [Kevin](https://slack.com/archives/C091185E1JN/p1770053550921979):** did I say IF? I meant WHEN
**09:32 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770053567802989):** already hit a roadblock. lets not get too excited! haha
**09:32 [Kevin](https://slack.com/archives/C091185E1JN/p1770053578724899):** ok back to IF
**09:53 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770054807018129):**
![[F0ACL779H1A_image.png]]
**09:53 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770054810635629):** we dont have the right licensing for plan A
**09:53 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770054813344319):** this is plan B
**10:13 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770056028335389):** @Kevin which PLC do you think would be best for alarm management? i see the WWTP micrologix. do they have any CLX anywhere?
**14:23 [Kevin](https://slack.com/archives/C091185E1JN/p1770071009202079):** Probably the ML at the reservoir
**14:23 [Kevin](https://slack.com/archives/C091185E1JN/p1770071015416349):** Tank 1
**14:24 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770071055694539):** im on plan C or D
**14:24 [Kevin](https://slack.com/archives/C091185E1JN/p1770071061205609):** Ok
**14:24 [Mason Radke](https://slack.com/archives/C091185E1JN/p1770071077981139):** if this works, i think i could also have signl4 acknowledge alarms in scada
**14:25 [Kevin](https://slack.com/archives/C091185E1JN/p1770071111020019):** Sweet