# PlatnPax Alarm Builder Alarm descriptions in Win911 Need to figure out how we need to go about changing the alarm descriptions that Win911 uses for the voice announcements. Screenshot from FTA&E: ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_36.png]] ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_34.png]] ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_35.png]] My understanding is Win911 uses the Message in FT A&E. Those messages are built by the alarm builder tool using the descriptions in the faceplates Current Alarm Builder Project is in Box\South County\ALARMS - Connect to PLC and 'Save' to upload the latest tag values into the offline file.  (this will take the changes made on SCADA faceplates and save them into the .ACD file)- copy this file to the scada server to a temp folder (Alarm builder tool works better from the scada server. something about permissions or connecting to certain project folders) If reconfiguring alarm builder xml files, goto the end for instructions.- open the PlantPax_Configuration tool using administrator privelages (if updating, skip to - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_27.png]] Skip to step 9 if HMI info is the same as another PLC- ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_22.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_28.png]] - - Select SE Distrubuted, Select the Application Name, browse for the project under c:\documents and users\all users\documents\rs view enterprise\SE\HMI Projects\WWTP_HMI- If HMI Application is the same as the other PLCs, use the copy/paste function (must know the Logix device shortcut name if you do this) ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_38.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_39.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_37.png]] - - You can leave the are name blank in the next pop up- ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_20.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_21.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_26.png]] check the controllers you wish to work with.- ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_25.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_30.png]] first right click and add a folder. The name is not critical, we will clean up on the A&E side after import. - check the alarms you wish to work with and drag them over to your new folder (or existing folder for updating)- ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_24.png]] tip- click and drag from the Controller column. only click in Select to select or deselect. - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_31.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_23.png]] select, use only tags from process tree then select the A&E server based polling alarms tab and select an output .xml file for it to save to.  overwrite is likely the option you will use here, append may be used depending on your import/update methods. - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_29.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_32.png]] - ![[PlatnPax_Alarm_Builder_Alarm_descriptions_in_Win911_image_33.png]] - the above screenshot option will depend on your import/update strategy Offline PLC files as of 2/17/25 Ctrl_Rm : Control_Room_240213* CCT : CCT_240724* H/M : HEATING_MIXING_240213* Influent : INFLUENT_PAX* MCC : MCC_PAX_240813* FFR : FFR_PAX_240213 * HW : HEADWORKS_PAX_V35 * CP4000 : WWTP_RP * To Update with alarm changes: Save updated PLC program to ACD Files for Alarm Builder 2 folder. (note if the program name has changed then you'll have to change the name of the ACD file to match the file name in ACD Files for Alarm Builder) Copy ACD files (rename if necessary) to ACD Files for Alarm Builder folder (not finished) CP4000 tag numbers to areas 40xx Feed 4060 Effluent 4211,4212,4215,4220,4221,4222,4225 Mixers 4213,4214,4216,4217,4227,4223,4224,4226,4227,4252 bubblers 43xx Blowers 44xx,46xx,47xx WAS 45xx RAS 70xx Rotary 93,95 Power Need to fix P5061 "Variable Speed Drive..." P_FFR1, P_FFR2 "Variable Speed Drive..." AIT_1002_Alm_Fail "Discrete Input Trip" P4711_MF, P4721_MF, VF4213,14,23,24

Extracted Entities

TypeKeyValueConfidenceEvidence
server Offline PLC File MCC MCC_PAX_240813* 90% MCC : MCC_PAX_240813*
server Offline PLC File FFR FFR_PAX_240213 * 90% FFR : FFR_PAX_240213 *
server Offline PLC File HW HEADWORKS_PAX_V35 * 90% HW : HEADWORKS_PAX_V35 *
server Offline PLC File CP4000 WWTP_RP * 90% CP4000 : WWTP_RP *
server HMI Projects Folder c:\documents and users\all users\documents\rs view enterprise\SE\HMI Projects\WWTP_HMI 90% browse for the project under c:\documents and users\all users\documents\rs view enterprise\SE\HMI Projects\WWTP_HMI
server Offline PLC Files Date 2/17/25 90% Offline PLC files as of 2/17/25
server Offline PLC File Ctrl_Rm Control_Room_240213* 90% Ctrl_Rm : Control_Room_240213*
server Offline PLC File CCT CCT_240724* 90% CCT : CCT_240724*
server Offline PLC File H/M HEATING_MIXING_240213* 90% H/M : HEATING_MIXING_240213*
server Offline PLC File Influent INFLUENT_PAX* 90% Influent : INFLUENT_PAX*
server ACD Files Folder ACD Files for Alarm Builder 80% Save updated PLC program to ACD Files for Alarm Builder 2 folder
server Alarm Builder Project Location Box\South County\ALARMS 80% Current Alarm Builder Project is in Box\South County\ALARMS
site Client SSLOCSD 100% Client: SSLOCSD
system Win911 Win911 100% changing the alarm descriptions that Win911 uses for the voice announcements
system Alarm Builder Tool Alarm Builder 90% alarm builder tool using the descriptions in the faceplates