# Reno's Survey Notes All T&M Overall - integrate all sites to communicate ethernet IP to main compactlogix - retag wonderware for new data connections - master airport meter, injection, and deerfield. we are adding waller park, jail lift station new level panel and possibly huber panel, reservoir pump station (only for new scada) Jail Lift Station - Level Sensor issue on huber panel. Not reading at all sometimes - intermittent analog - Kevin resolved this with a new analog card Need to replace level controls on main panel - two pump lead lag logic in daves controllogix program - level control is primary, flow control is backup Master Airport Flow Meter - new radio and possibly a micrologix with 1 analog input for flow, and maybe pulse - i suggest we use a click plc for modbus coms to the flowmeter and ethernet ip connection to the main controller - we have 12vdc at the site - is there a 12vdc click? Injection well - micro1100 - need to change out the radio and make sure the coms still work deerfield is micro1400. has existing radio. switch to new radio. will be on old scada tag replacement. critical alarm site Drying Beds - add the flow meter to old scada and the plcĀ  - land the flow meter to the plc - add tags to plc and old scada - the rest can be on new scada - compactlogix plc - may need to pull the program

Extracted Entities

TypeKeyValueConfidenceEvidence
site Jail Lift Station Jail Lift Station 90% Jail Lift Station - Level Sensor issue on huber panel
site Master Airport Master Airport Flow Meter 90% Master Airport Flow Meter - new radio and possibly a micrologix
site Injection Well Injection well 80% Injection well - micro1100 - need to change out the radio
site Deerfield deerfield 80% deerfield is micro1400. has existing radio. switch to new radio
site Drying Beds Drying Beds 70% Drying Beds - add the flow meter to old scada and the plc
site Waller Park waller park 70% we are adding waller park
site Reservoir Pump Station reservoir pump station 70% reservoir pump station (only for new scada)
system CompactLogix compactlogix 95% integrate all sites to communicate ethernet IP to main compactlogix
system Wonderware wonderware 90% retag wonderware for new data connections
system Click PLC click plc 85% i suggest we use a click plc for modbus coms to the flowmeter
system ControlLogix controllogix 85% two pump lead lag logic in daves controllogix program
system Micro1100 micro1100 80% Injection well - micro1100 - need to change out the radio
system Micro1400 micro1400 80% deerfield is micro1400. has existing radio