# #ccsd-water-ignition — 2026-03-02 **07:23 [Kevin](https://slack.com/archives/C08TVA84PD4/p1772464999227559):** @Mason Radke @andy do we need to have the CCSD meetings or did we cover it last time? **07:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772465317387439):** I think we covered it **07:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772465333919259):** I'll have an update by end of day **07:23 [Kevin](https://slack.com/archives/C08TVA84PD4/p1772464999227559):** @Mason Radke @andy do we need to have the CCSD meetings or did we cover it last time? **07:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772465317387439):** I think we covered it **07:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772465333919259):** I'll have an update by end of day **07:36 [andy](https://slack.com/archives/C08TVA84PD4/p1772465791567929):** Ok, yeah I wanted to just get a progress update on both the booster program and CCSD water **11:56 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772481409859539):** @andy for W3, i see IO in the opto at Slot 1/3 for di_W3_PK_Hi_Float_Failsafe but do not see an ACM instance for it in the IO list spreadsheet **11:57 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772481440742999):** i could bring it into one of the spares if that makes sense to you. **11:58 [andy](https://slack.com/archives/C08TVA84PD4/p1772481521942429):** It's abandoned intentionally **11:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772481531475039):** copy that! **11:58 [andy](https://slack.com/archives/C08TVA84PD4/p1772481532116779):** They’re going to be a handful of intentionally abandoned signals. **11:59 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772481544581899):** just want to confirm. im glad you know **12:00 [andy](https://slack.com/archives/C08TVA84PD4/p1772481623923719):** That signal used to be a physical leased copper line, they are no longer in service. **12:02 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772481775879129):** next item. SLOT 2/0 and SLOT 2/1 are both labelled do_W3_Turn_on_Pump in the PAC manager **12:07 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482041973139):** maybe i'll start a document or list as these questions may start to pile up **12:09 [andy](https://slack.com/archives/C08TVA84PD4/p1772482172281219):** That one I don't know. There should be a spreadsheet that has all of these items. The labeling impact managers should be for reference, but not the source of truth. If you can't find the spreadsheet let's find it **12:10 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482230473859):** i have the spreadsheet.. i'll cross reference. just curious since this is reading live data from the device. **12:10 [andy](https://slack.com/archives/C08TVA84PD4/p1772482232125659):** The labeling “in pac manager” **12:10 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482244597239):** but if one of the points has been identified for the run command in the spreadsheet i'll use it **12:13 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482386763799):** actually this is what im working on.. filling in the spreadsheet with the physical IO points in the optos to help me map in logix. **12:13 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482402058259):** the spreadsheet im looking at anyway doesnt specify the OPTO io points **12:15 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482512801979):** sorry i think found it **12:15 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482543137069):** ![[F0AJ6DUBTPE_image.png]] **12:15 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482547751739):** Output module/point **12:15 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482549279869):** 2/1 **12:15 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482554382159):** got it **12:19 [andy](https://slack.com/archives/C08TVA84PD4/p1772482751717789):** The otg files also have the IO labeled and laid out for each location, opened in EthernetIP configuration. Do you remember when we did that together? **12:19 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482770001079):** yeah i have all that open. **12:19 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482795863489):** which question are you referring to? the pump run command has been resolved. **12:20 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1772482807032479):** but i posted another question about the chlorine/turbidity

Extracted Entities

TypeKeyValueConfidenceEvidence
site CCSD Water CCSD 90% Ok, yeah I wanted to just get a progress update on both the booster program and CCSD water
system PAC Manager PAC manager 80% SLOT 2/0 and SLOT 2/1 are both labelled do_W3_Turn_on_Pump in the PAC manager
system EthernetIP Configuration EthernetIP configuration 70% The otg files also have the IO labeled and laid out for each location, opened in EthernetIP configuration
File: Clients/Tough/CCSD/slack/2026/03/2026-03-02_ccsd-water-ignition.md
Updated: 2026-03-02 21:45:20.264159