# #country-club — 2026-01-01 **07:44 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767282253992129):** ![[F0A6B42EL3G_image.png]] **07:44 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767282267160269):** can you help me understand FIC210_Out and FIC220_Out I/O points? **07:50 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767282608080349):** also the narrative talks about float switches that i dont see on the P&ID **07:59 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767283190102909):** also, the valves are "energize to open" but are also control valves? with a position command and feedback? how does the control work for them? **08:10 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767283818947279):** also i see a PLC at waller, a PLC at the west pond and two sets of RIO at the east pond? are there 3 PLCs? what type of RIO? **08:29 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767284975892759):** ![[F0A69REK9GD_image.png]] **08:49 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767286190476139):** alright, i think ive made sense of everything other than the Valve control. We have an Open/Close command and also a position and feedback? do we control the valve to maintain a flow rate? is the flow rate a setpoint? **09:10 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767287404844899):** assuming the valves maintain an operator setpoint for flow rate, let me know how this narrative reads to you. **09:12 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767287572959459):** [[F0A6DBSLGMQ_smcc_rw_control_package.pdf]] **09:29 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767288583157279):** hm since we have no AO cards im thinking that the PLC is not controlling the valve **10:00 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767290424719039):** [[F0A6H35LAMS_west_pond_plc_implementation.pdf]] [[F0A5Y23G33R_east_pond_plc_implementation.pdf]] **10:00 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767290433593069):** this is really just to help me wrap my head around the moving pieces.. **10:00 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767290445389529):** i think i have a good understanding of whats going on now **14:07 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767305239019879):** Sorry, just now seeing this! I don't know what's up with Slack notifications. Feel free to ping me on txt if you aren't getting a response. **14:08 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767305322685609):** Eh. It's a holiday. I think **14:11 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767305518191429):** true, but I've been in the office since 12 **14:12 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767305561423269):** There is a cla-val controller that will maintain the flow rate, like we setup at SMR for Andy **14:13 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767305585053719):** we will send a setpoint to the controller via modbus **14:22 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767306176808729):** Gotcha **14:23 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767306192969919):** And is it 3 PLCs? Or some sort of RIO? **14:34 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767306865405839):** There is a CLx at Waller, and three Productivity PLCs. **14:35 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767306944082089):** One of the ponds has two PLC’s? One for pump commands, and status? **14:36 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767307002643159):** there is a plc at one of the wells because it is remote from the pond (I think the East Pond East Well) **14:37 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767307028534119):** OK, and these three PLC’s will go back to the Waller CLX over ethernet radio? **14:38 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767307103610999):** correct. I would like each pond PLC to be in control of it's pond/well so that we aren't relying on comms to Waller. We will get a enable/disable from Waller, but want to have a bypass for it at each pond. **14:38 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767307109299299):** each pond has a HMI **14:39 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767307144437369):** Excellent. What type of HMI? **14:40 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767307213469589):** Cmore **15:37 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767310675707589):** Do you have them already? Know the model #s?

Extracted Entities

TypeKeyValueConfidenceEvidence
contact Mason Radke Mason Radke 100% 07:44 [Mason Radke](https://slack.com/archives/C093BAYNUEQ/p1767282253992129)
contact Kevin Kevin 100% 14:07 [Kevin](https://slack.com/archives/C093BAYNUEQ/p1767305239019879)
server Waller PLC Ethernet Radio ethernet radio 80% these three PLC’s will go back to the Waller CLX over ethernet radio?
site Laguna Country Club Laguna Country Club 90% Client: Laguna Document: Clients/Laguna/Country-Club
system Productivity PLC Productivity PLC 90% There is a CLx at Waller, and three Productivity PLCs.
system CLx CLx 90% There is a CLx at Waller, and three Productivity PLCs.
system Cmore Cmore 90% each pond has a HMI Cmore
task Ping Kevin on text Ping Kevin on text if no Slack response 80% Feel free to ping me on txt if you aren't getting a response.