**08:57 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773244634882439):**
![[F0ALBUVEKJ5_image.png]]
**08:57 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773244665644419):** I connect it to my network here and set it to dhcp and it shows up on linx but as a ?
**09:08 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245322053889):** That could be progress
**09:08 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245332379219):** Is it flashed?
**09:10 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773245417482949):** it is in the win CC environemtn watiting for a program
**09:10 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245441356499):** want the program to put on it?
**09:10 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773245446001119):** yes
**09:12 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245523088069):** looks like its in box
**09:12 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773245535419309):** copy
**09:12 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245539749119):** HMI program folder
**09:17 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773245874341659):** do I use application manager?
**09:18 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773245888090009):** Me file transfer utility
**09:18 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773245893415229):** thanks
**11:16 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773253012363799):** @AutoBot what is the login for sslocsd techconnect
**11:16 [AutoBot](https://slack.com/archives/C08G4KZG7D5/p1773253013337959):** :mag: Searching the vault…
**11:16 [AutoBot](https://slack.com/archives/C08G4KZG7D5/p1773253016573259):**
The login for Rockwell Automation TechConnect at SSLOCSD is:
- Username/Email: <mailto:sslocsd@outlook.com|sslocsd@outlook.com>
- Password: Keep!tFlowing22
This information is found in the client info under TECHCONNECT Rockwell Support email and password (Source: Clients/SSLOCSD/_client-info.md and Clients/SSLOCSD/slack/2026/03/2026-03-10_south-county.md).
:card_file_box: *Sources* (10 chunks):
• *SSLOCSD* — `Clients/SSLOCSD/SSLOCSD-DATA_server_WIMS_CONNECTOR.md`
• *SSLOCSD* — `Clients/SSLOCSD/slack/2026/03/2026-03-10_south-county.md`
• *SSLOCSD* — `Clients/SSLOCSD/emails/2026/february/SSLOCSD_IP_Address_Spreadsheet.md`
• *SSLOCSD* — `Clients/SSLOCSD/_client-info.md`
• *SSLOCSD* — `vault_files/DOMAIN_CONTROLLER_NOTES_image_2.png`
**11:27 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773253633816579):** chatting with support again
**11:27 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773253645522639):** oh.. keep me posted
**11:28 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773253705931359):** it was on RSLinx, then when I tried to send the file it wouldn't show up on the transfer utility.
**11:28 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773253709010349):** and no ping
**11:54 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255285438259):** they want me to factory reset it again.....
**11:55 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255317966009):** i'm about to pour water in side it and say, oh, now it doesn't turn on
**11:55 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255352463589):** autobot strike that from the record
**11:55 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255354893879):** lol
**11:56 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773255366025079):** haha
**12:01 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255664838219):** I should have just gotten them involved earlier yesterday
**12:01 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773255684565379):** yeah probably
**12:01 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773255696540409):** ive gone down the same rabbit holes
**12:01 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255716487179):** I usually avoid support like the plauge
**12:02 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773255760236779):** vary rarely am I like, oh so glad I called support
**12:38 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773257894661919):** factory reset and firmware installation is finished
**12:38 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773257905547199):** ok
**12:52 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773258770009679):** they asked me for the serial number, date of manufacture, and how long I've had it powered for. Now a NPSR ticket has been generated to return and replace the module
**12:53 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773258787782349):** NPSR?
**12:53 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773258789870719):** NPSR ticket number 4011462857
**12:53 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773258802239029):** ah for notes
**12:55 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773258902951449):** sent email to mychal at sslocsd and byron at royal
**12:57 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773259032259499):**
chat session record
``` Ursula: Hello, welcome to Rockwell Automation. My name is Ursula. How may I assist you today?
Kevin Seifert: continuation of ticket 4011461404
Ursula: please a moment, let me have a look at it.
Ursula: How can I help you?
Kevin Seifert: still unable to reach this hmi by ethernet after performing the steps suggested and those in article BF27859
Kevin Seifert: panel is currently in the FactoryTalk View ME Station screen with options to Load Application etc. It shows me an ip address on that screen but does not show up in FTLinx or does not respond to a ping
Kevin Seifert: I am connected directly to the same network switch by cable as the hmi
Kevin Seifert: note there were three blinking dots next to the DLR firmware version number in the firmware update mode when first updating the firmware
Kevin Seifert: search leads me to believe this is a hardware issue
Ursula: were you able to update the panel firmware ?
Kevin Seifert: yes
Kevin Seifert: V16
Ursula: Which IP address is shown on the "Terminal Settings-->Networks and Communications-->Network Connections-->Network Adapters-->IP Address"
Kevin Seifert: 192.168.50.101 255.255.255.0 192.168.50.1
Ursula: okay, have you tried to connect directly to the HMI?
Kevin Seifert: no
Ursula: please to connect directly to the HMI and see if it appear in Rslinx classic.
Kevin Seifert: trying now
Communication with the Oracle Service Cloud Chat service has been lost. Please wait while attempts are made to restore the connection.
Disconnection in 240 seconds.
Connection resumed.
Ursula: okay.
Kevin Seifert: not found in rslinx classic. my pc shows but no hmi
Ursula: are you able to ping it?
Kevin Seifert: no ping
Ursula: did you set your computer IP address and subnet to be in the same network as the HMI?
Kevin Seifert: standby
Ursula: okay.
Kevin Seifert: I set the IP of my NIC on PC (it was on automatic because I was connected to my network). tried ping again and checked RSLinx. still no ping and not on linx
Ursula: could you perform the factory default as specified in the technote BF27859, and tried to reconfigure oncemore the HMI
Kevin Seifert: I've already done that once. you want me to do it again?
Ursula: please try once more.
Kevin Seifert: I will update steps as I go
Kevin Seifert: entering maintenance mode
Ursula: okay.
Kevin Seifert: pressing factory default
Kevin Seifert: factory default in process
Ursula: okay.
Kevin Seifert: do I leave the network cable plugged directly to my pc?
Ursula: you can unplug it and complete the factory default first.
Kevin Seifert: now on the welcome to windows 10 IoT core screen...it is crunching away
Kevin Seifert: now on the rockwell automation screen
Ursula: okay.
Kevin Seifert: now at the Welcome to PanelView Plus screen
Kevin Seifert: clicking next
Kevin Seifert: setting administrator password
Ursula: okay.
Kevin Seifert: at the Network Adapters screen. Red error box lower left saying a network connection was not detected....click next?
Kevin Seifert: click next??
Kevin Seifert: clicking next
Ursula: YOU need to connect your computer to the HMI
Ursula: this is why it stating , " Red error box lower left saying a network connection was not detected"
Kevin Seifert: go back then?
Kevin Seifert: i went back, plugged in the ethernet cable to my pc. same error
Ursula: okay continue the procedure.
Kevin Seifert: saving and rebooting
Ursula: okay.
Kevin Seifert: now at firmware update utility
Kevin Seifert: note there are the three dots moving next to "current version" under DLR Network Switch Firmware
Kevin Seifert: I have V16 on a usb thumb drive
Ursula: use the USB to update the HMI/.
Kevin Seifert: ok, plugging in usb thumb drive and clicking Update from USB Storage
Kevin Seifert: now removing thumb drive after it says it is ok to remove, and clicking OK to continue
Kevin Seifert: hmi is now verifying and prepairing updates
Ursula: okay.
Kevin Seifert: alright, now at the Change Desktop Acess Password page. setting password
Ursula: okay.
Kevin Seifert: password set, starting factorytalk view me station
Kevin Seifert: me station is up.
Ursula: okay.
Kevin Seifert: what's next?
Ursula: try to connect with the HMI
Kevin Seifert: theres no ip address in the hmi
Ursula: Terminal Settings-->Networks and Communications-->Network Connections-->Network Adapters-->IP Address"
Kevin Seifert: you want me to set the ip address to 192.168.50.101
Ursula: set an IP address and subnet on the HMI of the same network as your computer.
Kevin Seifert: ok ip address set. do we need to do a reset?
Ursula: not\.
Ursula: *no
Kevin Seifert: ok
Kevin Seifert: no ping and nothing on linx
Ursula: okay, please provide the HMI serial number and manufacturing date.
Ursula: how long was the HMI powered?
Kevin Seifert: SN 323039090 2024/10/16
Kevin Seifert: I have had this powered for about 12 hours now
Ursula: the NPSR ticket was created to return and replace the module, 4011462857
Ursula: please contact your disrtibutor and provides the ticket number to continue the procedure.
Kevin Seifert: ok thank you
Ursula: your welcome.
Ursula: Thank you for chatting with us. Have a great day
```
**13:04 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773259472261109):** my conversation this morning with Claude
[[F0ALE06DND7_PanelView_Plus7_Troubleshooting_Chat.pdf]]
**13:22 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773260542760479):** @Mason Radke did you read through that server proposal?
**13:22 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260554499829):** no
**13:22 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773260575214639):** give it a read for me
**13:23 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260590995239):** can you add a task due today, i will forget
**13:24 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773260648356119):** it's ok, I'm just gonna send it
**13:24 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260686496489):** give it to claude and ask if there are any red flags
**13:24 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260688756519):** or anything to consider
**13:25 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773260714350939):** claude helped me write it
**13:25 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260727252989):** haha
**13:25 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773260733541569):** im sure its good
**13:25 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773260745272949):** I'll feed it to her anyway and see
**13:54 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773262467923019):** @Mason Radke here's the proposal for your enjoyment
[[F0ALVLWC3H6_SSLOCSD_SCADA_Upgrade_Proposal_2.pdf]]
**13:57 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773262649901519):**
Here's Claude's take on its work:
Good proposal overall — it's clean, professional, and well-structured. Here are some honest observations:
*Strengths first:* The phased approach is logical, the Bill of Materials is clear, and the exclusions section is actually quite good — explicitly calling out UPS, rack, cabling, and SCADA licensing protects you from scope creep disputes.
*Potential Red Flags / Areas to Improve:*
*Vague hardware specs in the BOM* The Memory Upgrade Kit just says "DDR4 ECC Registered RAM (to spec)" — that's not a real spec. If there's a dispute later about what was delivered, "to spec" is hard to enforce. Pin down the exact capacity (e.g., 128GB, 2x64GB DIMMs) and speed.
*No timeline or schedule* The proposal has no estimated completion date, phase durations, or project milestones. For a sanitation district managing critical infrastructure, they'll almost certainly want to know how long SCADA will be in a transitional/vulnerable state.
*Failover type is ambiguous* The proposal mentions "automated failover protocols" but doesn't specify whether this is a _hot standby_ (instant, automatic) or _warm standby_ (manual promotion required). That's a significant operational difference for a 24/7 facility, and it's exactly what the failover runbook will need to address.
*Hyper-V Replication lag isn't defined* Hyper-V Replication is asynchronous by default, with replication intervals as long as 5 minutes. For a SCADA system, acceptable data loss (RPO) should be explicitly stated — operators need to know how much data could be lost in a worst-case failover.
*No mention of who performs the failover* The runbook is listed as a deliverable, but there's no mention of training SSLOCSD staff to actually use it. A runbook sitting in a drawer that nobody has practiced is not a real DR plan.
*The $9,500 materials line is a lump sum* Breaking that out per-item (with unit costs) would be more transparent and easier to get approved through a public agency procurement process. Sanitation districts often have board approval thresholds that require itemized costs.
*Cybersecurity exclusion may be a liability* Excluding NERC CIP and cybersecurity hardening is understandable scope-wise, but for a public utility SCADA system, a brief note _recommending_ the district engage a cybersecurity review separately would be good practice — both for them and to show AutoSys is thinking about the bigger picture.
Overall it's solid work. The biggest practical gaps are the missing timeline and the underspecified failover behavior.
**14:39 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773265189941769):** @Mason Radke south county wants to have a meeting regarding this proposal. Not seeing anything on the calendar for us next week on monday. Is monday good for you?
**14:43 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773265395028019):** Yes
**14:43 [Mason Radke](https://slack.com/archives/C08G4KZG7D5/p1773265408821169):** Want to add a calendar item from here for it
**14:43 [Kevin](https://slack.com/archives/C08G4KZG7D5/p1773265430299919):** I need to create a meeting, so I'll do it manually