← Nino-Well

Clients/Nino-Well/_other-info.md

manual
Source
12
Chunks
0
Entities
Doc
Type

Content

# Nino-Well — Other Info > Auto-generated from ingested documents. Last updated: 2026-05-02 09:46 ## Other Info | Name | Details | |------|---------| | [ATO Inc Address](files/EM15-SP1%20110V-120V-input-VFD-user-manual.pdf) | 23555 GOLDEN SPRINGS DR. K-1, DIAMOND BAR, USA | | [Client Name](slack/2025/09/2025-09-05_nino-well) | Nino-Well | | [Client Plant](slack/2025/08/2025-08-27_nino-well) | Nino-Well | | [Device](slack/2025/09/2025-09-15_nino-well) | PLC | | [Grafana](slack/2025/07/2025-07-28_nino-well) | Grafana | | [MQTT](slack/2025/09/2025-09-06_nino-well) | MQTT used for communication between dashboard, Pi, and PLC | | [MQTT Broker](files/System_Access_Workflow_Documentation.docx) | HiveMQ Cloud | | [MQTT Server](slack/2025/09/2025-09-05_nino-well) | mqtt server | | [Modbus Protocol](slack/2025/08/2025-08-10_nino-well) | Modbus | | [Nino-Well](slack/2025/11/2025-11-05_nino-well) | Nino-Well | | [Node-RED](slack/2025/09/2025-09-06_nino-well) | Node-RED logic re-organized with scheduler and MQTT communication | | [Operating System](slack/2025/07/2025-07-05_nino-well) | Pi OS Lite 64bit | | [PI](slack/2025/11/2025-11-05_nino-well) | PI | | [PLC](slack/2025/11/2025-11-06_nino-well) | PLC | | [Productivity Software](slack/2025/07/2025-07-06_nino-well) | Productivity software | | [Productivity Suite](slack/2025/08/2025-08-27_nino-well) | Productivity installed on office PC | | [Putty](slack/2025/07/2025-07-06_nino-well) | Putty | | [Raspberry Pi Model](files/System_Access_Workflow_Documentation.docx) | Raspberry Pi 5 | | [Starlink](slack/2025/09/2025-09-05_nino-well) | starlink | | [Time-series Database](files/System_Access_Workflow_Documentation.docx) | InfluxDB Cloud | | [Uptime Monitoring Service](files/System_Access_Workflow_Documentation.docx) | Healthchecks.io | | [Visualization Platform](files/System_Access_Workflow_Documentation.docx) | Grafana Cloud | | [device](slack/2025/10/2025-10-10_nino-well) | Pi | | [device](slack/2025/10/2025-10-10_nino-well) | Starlink | | [product](slack/2025/07/2025-07-08_nino-well) | Starlink | | [protocol](slack/2025/07/2025-07-08_nino-well) | modbus tcp | | [protocol](slack/2025/07/2025-07-07_nino-well) | MQTT | | [software on Pi](slack/2025/07/2025-07-07_nino-well) | node-red | | [ATO Inc Website](files/EM15-SP1%20110V-120V-input-VFD-user-manual.pdf) | https://www.ato.com/ | | [Device](slack/2025/09/2025-09-15_nino-well) | pi | | [Grafana dashboard URL](slack/2025/07/2025-07-28_nino-well) | https://autosys.grafana.net/d/mak6p28/autosys?orgId=1&from=now-6h&to=now&timezone=browser&refresh=auto | | [PLC](slack/2025/07/2025-07-06_nino-well) | PLC | | [PLC Com Port Parameters](slack/2025/08/2025-08-27_nino-well) | 9600 8N2 node 1 | | [PLC Device](slack/2025/09/2025-09-05_nino-well) | PLC | | [Pi Device](slack/2025/09/2025-09-05_nino-well) | pi | | [Pi ethernet IP address after DHCP](slack/2025/07/2025-07-07_nino-well) | 10.0.0.x | | [Raspberry Pi](slack/2025/07/2025-07-06_nino-well) | Pi | | [VPN Device](slack/2025/08/2025-08-27_nino-well) | pi | ## Tasks & Action Items - **Action Item:** Install a bigger battery to prevent power dropouts — [[slack/2025/09/2025-09-15_nino-well]] - **Action Item:** Investigate logs to determine if Pi is rebooting — [[slack/2025/09/2025-09-15_nino-well]] - **Action Item:** Set important tags to retentive to retain values across reboots — [[slack/2025/09/2025-09-15_nino-well]] - **Add digital output card to PLC:** Owner: Mason Radke — [[slack/2025/08/2025-08-29_nino-well]] - **Add time clock option:** Add time clock option for automatic well start/stop by time of day — [[slack/2025/09/2025-09-06_nino-well]] - **Comm Fail Alert Setup:** Set up communication failure alert system — [[slack/2025/09/2025-09-05_nino-well]] - **Fix dashboard data:** Owner: Mason Radke — [[slack/2025/08/2025-08-29_nino-well]] - **Implement run timer logic:** Owner: Mason Radke — [[slack/2025/08/2025-08-29_nino-well]] - **PLC Programming:** Program PLC to start VFD from DO 1 — [[slack/2025/09/2025-09-05_nino-well]] - **Power Cycle Device:** Power cycle drive and Pi to resolve timeout — [[slack/2025/08/2025-08-27_nino-well]] - **Power Pi from 24V:** Power the Pi device from 24 volts — [[slack/2025/09/2025-09-05_nino-well]] - **Power cycle equipment:** Power cycle equipment at Nino-Well — [[slack/2025/11/2025-11-05_nino-well]] - **Test scheduler:** Start the well for a couple minutes to test the scheduler — [[slack/2025/09/2025-09-06_nino-well]] - **Update Modbus Registers:** Update registers for different VFD model — [[slack/2025/08/2025-08-27_nino-well]] - **Use DO for start/stop:** Use digital output (DO) for start/stop control of well — [[slack/2025/09/2025-09-06_nino-well]] - **action item:** look into Starlink options — [[slack/2025/07/2025-07-08_nino-well]] - **action item:** confirm VFD has modbus TCP — [[slack/2025/07/2025-07-08_nino-well]] - **action item:** get Corky a bid — [[slack/2025/07/2025-07-08_nino-well]] ## Contacts | Name | Details | |------|---------| | [ATO Inc Phone](files/EM15-SP1%20110V-120V-input-VFD-user-manual.pdf) | 1800-585-1519 | | [Kevin](slack/2025/11/2025-11-05_nino-well) | Kevin | | [Mason Radke](slack/2025/11/2025-11-05_nino-well) | Mason Radke | | [Person](slack/2025/08/2025-08-29_nino-well) | Mason Radke | | [Person](slack/2025/08/2025-08-10_nino-well) | Kevin | | [Person Name](slack/2025/09/2025-09-13_nino-well) | Kevin | | [Person Name](slack/2025/09/2025-09-15_nino-well) | Mason Radke |
File: Clients/Nino-Well/_other-info.md
Updated: 2026-05-02 16:48:21.253316