# #ccsd-water-ignition — 2026-03-26 **07:13 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774534423056399):** @andy i was waiting on a few things from you here. Lets start with rodeo grounds. you were going to tell me which DOs are used for control and how the logic works and if we need separate on /off commands **07:29 [andy](https://slack.com/archives/C08TVA84PD4/p1774535357253779):** I’m going to head out there to confirm this. Would you like to huddle while I’m there or you just need to know which outputs and how they work? Of course, if there are any other questions now would be a great time for me to do on site investigation. **07:29 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774535390723889):** just need to know which outputs and if we need to use both the on and off commands **07:30 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774535416266299):** i will go through our notes and see what other questions i needed answers on. **08:38 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774539483258849):** we decided that both SR3 and SR4 do not need me to do any programming work? can you confirm that? > **08:42 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774539744857639):** Thread Started **08:50 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774540244526739):** how are we programming the DO resets for the rodeo grounds boosters? what logic will trigger those DOs? > **08:50 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774540251380759):** thread started **11:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774548062687419):** how can i get the run output to trigger in your plantpax P_motor? how does inp_call play in? if i put it in sim, do i need to set it to program mode or operator mode? what are the gates that must be true for the output to energize? trying to test this pulse logic **11:16 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549006534209):** ![[F0AP4E4J3DY_image.png]] **11:16 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549019639489):** ok, my test bit represents the out_run status of the object. **11:17 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549036766839):** this will hold the on command for X seconds when the AOI energizes out_run **11:17 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549070350929):** and release it and hold the off command for X seconds when the out_run drops **11:18 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549111536069):** oops, i have the commands swapped, but the idea is the same **11:26 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549591378379):** ![[F0AP4G3M60J_image.png]] **11:26 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549606752599):** your custom hmi reset parameter for the p_motor object is an input parameter **11:26 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549614138159):** we wont be able to tie an output to that in function block **11:27 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549641193079):** i might be able to do it in ladder, would just require an entire new routine for one rung. **11:28 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774549690172599):** or further modifying the AOI to have a reset output **11:36 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774550185841459):** ![[F0ANP5GRDNK_image.png]] **11:36 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774550217349959):** just gonna make a resets routing and put all of our DOs for resets here for now **11:54 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774551248369029):** ![[F0ANYB259NX_image.png]] **12:01 [AutoBot](https://slack.com/archives/C08TVA84PD4/p1774551717138609):** CCSD Water — SNAP IO Tracker: 100% Complete **12:17 [andy](https://slack.com/archives/C08TVA84PD4/p1774552637062629):** Awesome, that's great **12:18 [andy](https://slack.com/archives/C08TVA84PD4/p1774552698810059):** I need to get the router licensed to allow SR4 to communicate and we can finish that. Now that the IO is setup via comms are they wired into the PAX objects? **12:18 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774552728661809):** there are two progress % for each site **12:19 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774552743952279):** one represents the modbus IO and the other is the PAX progress **12:19 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774552765133899):** PAX Done: 120/120 (100%) **12:21 [andy](https://slack.com/archives/C08TVA84PD4/p1774552868150439):** Gotcha I didn’t see that yet. It’s I’m looking on my phone. I just finished a meeting with Cambria. **12:21 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774552882051279):** we're looking good **12:43 [andy](https://slack.com/archives/C08TVA84PD4/p1774554207494859):** Can you send me your ACD file so I can check it? **12:44 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554243825569):** this was all done online.. do you want me to send you a copy? **12:45 [andy](https://slack.com/archives/C08TVA84PD4/p1774554300390729):** Yeah please **12:45 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554305461699):** k, standby **12:45 [andy](https://slack.com/archives/C08TVA84PD4/p1774554323154059):** And the Prosoft's config file **12:45 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554355637629):** [[F0AP8MJU4S0_Opto22_Prosoft_032626.ppf]] **12:47 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554445022149):** [[F0ANYNH84H1_CLX_SCADA_CCSD_Water20260326.ACD]] **12:49 [andy](https://slack.com/archives/C08TVA84PD4/p1774554590880049):** Thanks **12:50 [andy](https://slack.com/archives/C08TVA84PD4/p1774554631324099):** So right now it’s online and reading from all of the RTU’s and the right commands are inhibited? Where is it at functionally **12:50 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554645618959):** correct. write commands are all disabled in the prosoft **12:51 [andy](https://slack.com/archives/C08TVA84PD4/p1774554686687549):** And have you looked at the Ignition side to see how it is behaving with all of this new data or you’ve just been focusing on the studio side **12:52 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554750185109):** as far as im aware i was to figure out the OPTO22 IO comms and get it wired up in the PLC. i have not done anything in ignition **12:53 [andy](https://slack.com/archives/C08TVA84PD4/p1774554782206669):** Yes, I ran with the Ignition side, I’m just trying to see where things are at before I dive in. **12:55 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774554925419599):** this was a big job, im sure we will have some fine tuning to do. **12:55 [andy](https://slack.com/archives/C08TVA84PD4/p1774554941465739):** For sure **12:56 [andy](https://slack.com/archives/C08TVA84PD4/p1774554983420269):** I know I’ve asked you this, but I can’t remember, when you set up the messaging to the Io, did you read the entire card or just the points required? **12:57 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555029654589):** depends. and if i were to start from scratch i would do it little different. there was a lot of learning involved for the first half. **12:57 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555065760179):** whole card is read in when necessary. sometimes just the one point.. especially for writes **12:57 [andy](https://slack.com/archives/C08TVA84PD4/p1774555079190619):** They just asked me about adding some points and I need to know what is involved for me to add another future point or tweak something you know **12:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555081154209):** its all labled in comments in the PLC IO tag for the modbus stuff **12:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555095884749):** as far as cards/points and how they're organized **12:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555118237999):** we may be able to extend a modbus command if there is room in the internal database and the IO tag array **12:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555123974929):** otherwise we will need to add it to the end **12:58 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774555126947009):** with its own command **12:58 [andy](https://slack.com/archives/C08TVA84PD4/p1774555131512079):** Right **14:56 [andy](https://slack.com/archives/C08TVA84PD4/p1774562174689919):** I’ll be reviewing this tomorrow FYI, thank you for your work today and the updates. **14:57 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774562231274209):** no problem! it was next on the list. i had just one high priority thing to knock out and then i was going to finish it up. **14:59 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774562348855819):** as we get busier, its just going to be important to communicate dates as early as possible. i wont be able to keep track unless its documented. we have a good system in place now for scheduling my work.. lets take advantage and block out dates you will need assistance or need a projoect by asap.

Extracted Entities

TypeKeyValueConfidenceEvidence
contact person name Mason Radke 100% 07:13 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1774534423056399)
contact person name andy 100% 07:29 [andy](https://slack.com/archives/C08TVA84PD4/p1774535357253779)
site plant name CCSD Water 100% 12:01 [AutoBot](https://slack.com/archives/C08TVA84PD4/p1774551717138609): CCSD Water — SNAP IO Tracker
system product name Ignition 100% 12:51 [andy]: And have you looked at the Ignition side to see how it is behaving
system product name Prosoft 100% 12:45 [Mason Radke]: [[F0AP8MJU4S0_Opto22_Prosoft_032626.ppf]]
system product name PlantPAx 90% 11:01 [Mason Radke]: how can i get the run output to trigger in your plantpax P_motor?
system product name OPTO22 90% 12:52 [Mason Radke]: i was to figure out the OPTO22 IO comms and get it wired up in the PLC