Content

# #ccsd-water-ignition — 2026-04-20 **08:55 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700533706889):** [[F0AU30DP7R8_CCSD_Data_Collector_67.html]] **08:55 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700556645279):** @andy documentation updated to include per site read and write disable commands **08:56 [andy](https://slack.com/archives/C08TVA84PD4/p1776700585493069):** Beautiful thank you **08:56 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700588697269):** comm routine is 177 rungs **08:56 [andy](https://slack.com/archives/C08TVA84PD4/p1776700609975169):** Actual logic is like 15 **08:57 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700626779269):** haha yah. **08:58 [andy](https://slack.com/archives/C08TVA84PD4/p1776700707162379):** That’s the same proportion of overtime and service call cost **09:00 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700843219659):** sounds about right.. i still need to go through all the function block and update the inp_PVBad or IOfault with the disable commands **09:00 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700847227339):** gonna take a minute **09:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700895669299):** but for your scada work you should be good to **09:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700899062989):** using that latest HTML **09:02 [andy](https://slack.com/archives/C08TVA84PD4/p1776700925258099):** Right thank you **09:08 [andy](https://slack.com/archives/C08TVA84PD4/p1776701332475739):** My client is saying rodeo grounds pumps are turning on and off every 10 seconds or so **09:09 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776701344940419):** thats not good. let me take a look **09:09 [andy](https://slack.com/archives/C08TVA84PD4/p1776701352888969):** Maybe you have the enable bit mapped wrong or something **09:16 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776701778155419):** it was enabled.. my per site logic did a one shot enabling everything. **09:16 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776701782228289):** i need to shut down the writes again **09:18 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776701914755699):** ok, all writes disabled. **09:18 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776701930953969):** using the new per site write disable commands **09:19 [andy](https://slack.com/archives/C08TVA84PD4/p1776701941403109):** Ok **09:19 [andy](https://slack.com/archives/C08TVA84PD4/p1776701948300289):** I’ll have them out into auto and test **09:23 [andy](https://slack.com/archives/C08TVA84PD4/p1776702184578009):** ![[F0AU15P2154_IMG_1411]] **09:23 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776702196304379):** excellent **09:23 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776702215660859):** good end-2-end test right there. **09:23 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776702217023589):** we have control **09:24 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776702291620179):** [[F0AU6RCJWS0_CCSD_Data_Collector_68.html]] **13:00 [Kevin](https://slack.com/archives/C08TVA84PD4/p1776715237914789):** wonder why they were going on and off **13:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776715280783009):** I’m sure local logic was telling it to run and we were writing a stop command to it **13:01 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776715289984249):** It’s a pulse on pulse off set up

Extracted Entities

TypeKeyValueConfidenceEvidence
contact Mason Radke Mason Radke 100% 08:55 [Mason Radke](https://slack.com/archives/C08TVA84PD4/p1776700533706889)
contact andy andy 100% 08:56 [andy](https://slack.com/archives/C08TVA84PD4/p1776700585493069)
contact Kevin Kevin 100% 13:00 [Kevin](https://slack.com/archives/C08TVA84PD4/p1776715237914789)
site Rodeo Grounds Pumps Rodeo Grounds 90% My client is saying rodeo grounds pumps are turning on and off every 10 seconds
system SCADA System SCADA 80% but for your scada work you should be good to using that latest HTML