AMWC

48
Documents
183
Entities
115
Chunks

Documents

DocumentSourceUpdated
📄 Clients/AMWC/_other-info.md manual 2026-05-02 16:46:28.151183 View →
📄 Clients/AMWC/_equipment-info.md manual 2026-05-02 16:46:26.843649 View →
📄 Clients/AMWC/_credentials.md manual 2026-05-02 16:46:19.212235 View →
📄 Clients/AMWC/_network-info.md manual 2026-05-02 16:46:18.882756 View →
Clients/AMWC/emails/2026/march/VPN.md gmail 2026-03-11 23:58:46.994979 View →
Clients/AMWC/emails/.raw/2026/march/Re_VPN_1.md gmail 2026-03-11 23:54:41.978358 View →
Clients/AMWC/emails/.raw/2026/march/Re_VPN.md gmail 2026-03-11 23:54:16.449681 View →
📄 Clients/AMWC/remarkable/Cencero/Commissioning.md manual 2026-03-10 19:12:57.781658 View →
📄 Clients/AMWC/VPN Login.md manual 2026-03-09 19:23:57.101008 View →
📄 Clients/AMWC/files/SYC-VEND-VPN-AUTOSYS-MRADKE.conf gdrive 2026-03-05 22:50:14.092812 View →
📄 Clients/AMWC/slack/2026/02/2026-02-10_amwc.md slack 2026-02-25 04:40:18.148043 View →
📄 Clients/AMWC/slack/2026/02/2026-02-09_amwc.md slack 2026-02-25 04:40:18.088521 View →
📄 Clients/AMWC/slack/2026/01/2026-01-26_amwc.md slack 2026-02-25 04:40:18.052461 View →
📄 Clients/AMWC/remarkable/Cencero/Pressure_PID/Presure_control.md manual 2026-02-25 04:40:18.037877 View →
📄 Clients/AMWC/remarkable/Cencero/Pressure_PID/Rung_changes.md manual 2026-02-25 04:40:18.024431 View →
📄 Clients/AMWC/remarkable/Summit_Hills/Summit_Hills.md manual 2026-02-25 04:40:18.008232 View →
📄 Clients/AMWC/remarkable/Del_Rio/Alarms.md manual 2026-02-25 04:40:17.995567 View →
📄 Clients/AMWC/remarkable/VPN.md manual 2026-02-25 04:40:17.786028 View →
📄 Clients/AMWC/evernote/San_Marcos_tags.md evernote 2026-02-25 04:40:17.282433 View →
📄 Clients/AMWC/evernote/AMWC_SCADA_Notes.md evernote 2026-02-25 04:40:17.109566 View →
📄 Clients/AMWC/evernote/Network_Info.md evernote 2026-02-25 04:40:17.050110 View →
📄 Clients/AMWC/evernote/San_Marcos_Panel_Refresh.md evernote 2026-02-25 04:40:17.023343 View →
📄 Clients/AMWC/evernote/VPN.md evernote 2026-02-25 04:40:16.958756 View →
📄 Clients/AMWC/evernote/Well_5a_PLC_Refresh.md evernote 2026-02-25 04:40:16.898306 View →
📄 Clients/AMWC/evernote/Well_5a_Commissioning.md evernote 2026-02-25 04:40:16.869708 View →
📄 Clients/AMWC/evernote/173_Radio_Testing.md evernote 2026-02-25 04:40:16.745158 View →
📄 Clients/AMWC/remarkable/Cencero/Pressure_PID/Pump1.pdf manual 2026-02-24 05:25:51.067555 View →
📄 Clients/AMWC/remarkable/Cencero/Pressure_PID/Pump_Routine.pdf manual 2026-02-24 05:25:40.800258 View →
📄 Clients/AMWC/remarkable/Cencero/AMWC_-_CENCERRO_20250314.pdf manual 2026-02-24 05:25:04.576292 View →
📄 Clients/AMWC/remarkable/Cencero/Converted_Studio_5000_Tag_List.pdf manual 2026-02-24 05:24:57.538690 View →
📄 Clients/AMWC/remarkable/Cencero/RTU21_Cencero_Controller_Tags.pdf manual 2026-02-24 05:24:45.612304 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/SCADA_IN.pdf manual 2026-02-24 05:24:12.783740 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/PUMP2.pdf manual 2026-02-24 05:24:01.989376 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/SCADA_OUT.pdf manual 2026-02-24 05:23:55.653684 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/AI_SCALING.pdf manual 2026-02-24 05:23:46.738199 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/PUMP1.pdf manual 2026-02-24 05:23:39.827269 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/RTC.pdf manual 2026-02-24 05:23:33.251323 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/MISC.pdf manual 2026-02-24 05:23:26.314424 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/Main.pdf manual 2026-02-24 05:23:15.780760 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/PUMP3.pdf manual 2026-02-24 05:23:02.815751 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/ALARMS.pdf manual 2026-02-24 05:22:54.738857 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/PUMPS.pdf manual 2026-02-24 05:22:40.647975 View →
📄 Clients/AMWC/remarkable/Cencero/SLC_Program/OIT.pdf manual 2026-02-24 05:22:28.854939 View →
📄 vault_files/Snapshot.png manual 2026-02-20 04:21:03.722902 View →
📄 vault_files/Snapshot.jpg manual 2026-02-20 04:20:49.229550 View →
📄 vault_files/San_Marcos_tags_Snapshot_1.png manual 2026-02-20 03:55:35.701339 View →
📄 vault_files/San_Marcos_tags_Snapshot.png manual 2026-02-20 03:55:17.427012 View →
📄 vault_files/Network_Info_Snapshot.jpg manual 2026-02-20 03:12:49.485748 View →

Entities

TypeKeyValueConfidenceEvidence
contact Chris Schaab Email cschaab@amwc.us 100% To: Chris Schaab <cschaab@amwc.us>
contact person name Kevin 100% 09:19 [Kevin](https://slack.com/archives/C0AAMNVGBN3/p1770657594948439)
contact Matt Sytsma Email msytsma@amwc.us 100% To: Matt Sytsma <msytsma@amwc.us>
contact person name Mason Radke 100% 09:04 [Mason Radke](https://slack.com/archives/C0AAMNVGBN3/p1770656646408639)
contact Christian Schaab Phone 805.464.5344 100% P: 805.464.5344
contact Network Administrator Christian Schaab 100% Christian Schaab Network Administrator Atascadero Mutual Water Company
contact Network Administrator phone 805-464-5344 100% 805-464-5344 | cschaab@amwc.us
contact Network Administrator email cschaab@amwc.us 100% 805-464-5344 | cschaab@amwc.us
contact Chris Schaab email cschaab@amwc.us 100% From: Chris Schaab <cschaab@amwc.us>
contact email cschaab@amwc.us 100% To: Chris Schaab <cschaab@amwc.us>
contact email msytsma@amwc.us 100% To: Matt Sytsma <msytsma@amwc.us>
contact email mason@autosysnet.com 100% From: Mason Radke <mason@autosysnet.com>
contact phone number 805.464.5344 100% P: 805.464.5344
contact Network Administrator Christian Schaab 100% Christian Schaab | Network Administrator
contact person name Kevin 100% 13:40 Kevin: really? is it your tailscale causing a storm?
contact person name Mason Radke 100% 12:00 Mason Radke: When my computer plugs into one of these sites all of the 900mhz radios go down.
contact Chris Schaab phone 805.464.5344 100% P: 805.464.5344
contact Mason Radke email mason@autosysnet.com 100% From: Mason Radke <mason@autosysnet.com>
contact Company Website https://nviro.com/ 100% NVIRO https://nviro.com/
contact Christian Schaab Name Christian Schaab 100% Christian Schaab | Network Administrator
contact Mason Radke Email mason@autosysnet.com 100% From: Mason Radke <mason@autosysnet.com>
contact Steven Engineering Phone (800) 258-9200 95% Phone number: (800) 258-9200
contact Steven Engineering Website www.StevenEngineering.com 95% website www.StevenEngineering.com
contact Steven Engineering Phone (800) 258-9200 95% (800) 258-9200 fajita
contact Steven Engineering Website www.StevenEngineering.com 95% www,StevenEngineering- .com
contact Steven Engineering Phone (800) 258-9200 90% phone number (800) 258-9200
contact Company Contact Phone (888) 88 NVIRO 80% Designed By: (888) 88 NVIRO San Luis Obispo, CA 93401
credential Stratus console and HMI Windows server login username: mradke / password: Refuse2-Follow-Cheer 100% Username: mradke Password: Refuse2-Follow-Cheer
credential VPN PrivateKey 8DKfKhDGmaeuWJ+2ieqYnDEpsFqNQpqwRDJtzP/J5Gs= 100% PrivateKey = 8DKfKhDGmaeuWJ+2ieqYnDEpsFqNQpqwRDJtzP/J5Gs=
credential VPN Password Hangup4-Stylus-Crumb 100% Password is Hangup4-Stylus-Crumb
credential VPN Password Hangup4-Stylus-Crumb 100% Password is Hangup4-Stylus-Crumb
credential SCADA Login username: Mike / password: HoleIn1! 95% SCADA Login Mike HoleIn1!
credential RUT Modem Login username: 705-284-855-590 / password: Nviro#88 95% RUT 705-284-855-590 Nviro#88
credential Modem Login username: admin / password: Nviro#88 95% Modem Login admin Nviro#88
credential SCADA Login username: amwc\mradke / password: Refuse2-Follow-Cheer 90% amwc\mradke Refuse2-Follow-Cheer be sure to include the domain name
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
_no_entities no_text_content 0%
_no_entities backfilled 0%
_no_entities backfilled 0%
server Stratus console 10.10.200.10 100% via the Stratus console on 10.10.200.10
server FT Studio VM (HMI) 10.10.200.14 100% FT Studio is on 10.10.200.14 (VM is called HMI)
server Chalk Mnt IP 172.16.13.1 100% Chalk Mnt        172.16.13.1
server Random Oaks IP 172.16.13.7 100% Ping statistics for 172.16.13.7
server Well 8 IP 172.16.13.8 100% Ping statistics for 172.16.13.8
server Viejo Camino IP 172.16.13.36 100% Ping statistics for 172.16.13.36
server Ethernet Radio Model INET-900-IP 100% RADIO MDS INET-900-IP
server Data concentrator 10.10.200.200 100% The data concentrator is at 10.10.200.200 and is accessible from the HMI server
server PLC IP address 10.10.200.200 100% not able to hit any of the servers or the PLC at 10.10.200.200
server 1756-ENBT Module IP Address 172.16.100.100 95% "Module IP Address:" 172 . 16 . 100 . 100
server Steven Engineering Website www.StevenEngineering.com 95% Website: www.StevenEngineering.com
server RTU Identifier RTU-21 90% RTU-21 20240124 LAD 12 - PUMP3 --- Total Rungs in File = 16
server RTU Identifier RTU-21 90% RTU-21 20240124
server PLC IP Address 10.10.200.200 90% not able to hit any of the servers or the PLC at 10.10.200.200
server RTU Identifier RTU-21 90% RTU-21 PID Updates
server 1756-ENBT Subnet Mask 255.255.255.0 90% "Subnet Mask:" 255 . 255 . 255 . 0
server 1756-ENBT Gateway Address 172.16.100.120 90% "Gateway Address:" 172 . 16 . 100 . 120
server Primary DNS Server 8.8.8.8 90% "Primary DNS Server Address:" 8 . 8 . 8 . 8
server RTU Identifier RTU-21 90% RTU-21 20240124 LAD 10 - PUMP1 --- Total Rungs in File = 16
server RTU Identifier RTU-21 90% RTU-21 20240124 LAD 9 - PUMPS --- Total Rungs in File = 43
server RTU Identifier RTU-21 90% RTU-21 20240124 LAD 4 - SCADA IN --- Total Rungs in File = 16
server PLC IP Address 10.10.200.200 90% servers or the PLC at 10.10.200.200
server RTU Identifier RTU-21 20240124 90% RTU-21 20240124 LAD 3 - OIT --- Total Rungs in File = 8
server Module IP Address 172.16.100.100 90% Module IP Address: 172 . 16 . 100 . 100
server Subnet Mask 255.255.255.0 90% Subnet Mask: 255 . 255 . 255 . 0
server Gateway Address 172.16.100.120 90% Gateway Address: 172 . 16 . 100 . 120
server Primary DNS Server Address 8.8.8.8 90% Primary DNS Server Address: 8 . 8 . 8 . 8
server RTU Identifier RTU-21 90% RTU-21 PID Updates
server RTU Device RTU-21 90% RTU-21 20240124 LAD 6 - AI SCALING
server Pump 3 AB VFD IP 192.168.16.62 90% Pump 3 AB VFD IP: 192.168.16.62
server PLC IP 172.16.100.6 90% PLC IP: 172.16.100.6
server GE MDS 173 radio IP 172.16.13.100 90% GE MDS 173 radio 172.16.13.100 255.255.0.0
server DATA COLLECTOR PLC IP 10.10.200.200 90% DATA COLLECTOR PLC - 10.10.200.200
server DATA COLLECTOR NIC 2 IP 172.16.100.100 90% DC NIC 2 172.16.100.100 255.255.255.0
server DATA COLLECTOR NIC 3 IP 172.16.100.101 90% DC NIC 3 172.16.100.101
server DATA COLLECTOR CELL MODEM IP 172.16.100.101 90% DATA COLLECTOR CELL MODEM - 172.16.100.101
server DATA COLLECTOR MODEM STATIC PUBLIC IP 100.81.16.133 90% STATIC PUBLIC IP FOR DATA COLLECTOR MODEM - 100.81.16.133
server DELL RIO PLC IP 172.16.100.121 90% DELL RIO PLC - 172.16.100.121
server DELL RIO CELL MODEM IP 172.16.100.120 90% DELL RIO CELL MODEM - 172.16.100.120
server DELL RIO MODEM STATIC PUBLIC IP 100.126.104.33 90% STATIC PUBLIC IP FOR DELL RIO MODEM - 100.126.104.33
server Input Module 1746-IB16 80% 1746-IB16 Pump 1 Running
server PLC Input Points for UPS Status I:0/3, I:0/4, I:0/5 80% Well 25 PLC has inputs landed at I:0/3, I:0/4, I:0/5 for UPS status
server HMI IP 172.16.100.66 80% HMI IP: 172.16.100.66
server Secondary DNS Server Address 0.0.0.0 80% Secondary DNS Server Address: 0 . 0 . 0 . 0
server PLC Input Point I:1/12 80% Well 5a PLC has an input landed at I:1/12 labelled Desander Valve in Auto
server PLC Input Point I:1/11 80% Well 5a PLC has an input landed at I:1/11 labelled Phase Failure
server PLC Input Point I:1/6 80% Well 5a PLC has an input landed at I:1/6 labelled Well 5a Low Discharge Pressure
server PLC Input Point I:1/5 80% Well 5a PLC has an input landed at I:1/5 labelled Well 5a High Discharge Pressure
server Analog Inputs in Well 25 PLC I:1.0, I:1.1, I:1.2, I:1.3, I:2.0, I:2.1, I:2.2, I:2.3 80% Several analog inputs not seen in the well 5a code... I:1.0, I:1.1, I:1.2, I:1.3, I:2.0, I:2.1, I:2.2, I:2.3
server Secondary DNS Server 0.0.0.0 80% "Secondary DNS Server Address:" 0 . 0 . 0 . 0
server PLC Input Point I:1/13 80% Well 5a PLC has an input landed at I:1/13 labelled Waste Valve in Auto
server network types 173, 400, and 900Mhz radio telemetry networks 70% They have a combination of 173, 400, and 900Mhz radio telemetry networks
server Ethernet Radio IP Address 192.168.1.x 70% MDS INET-900-IP 192.168.1.x
site Client Name AMWC 100% Client: AMWC
site Pump Station Name Cencerro Pump Station 100% AMWC RTU 21 - CENCERRO PUMP STATION ELECTRICAL & CONTROLS
site Client Name AMWC 100% Client: AMWC
site Client Name AMWC 100% Client: AMWC
site Client Name Atascadero Mutual Water Company 100% Atascadero Mutual Water Company
site Client AMWC 100% Client: AMWC
site Client Name Atascadero Mutual Water Company 100% Atascadero Mutual Water Company
site Client Name AMWC 100% AMWC RTU 21 - CENCERRO PUMP STATION
site Client company Atascadero Mutual Water Company 100% Atascadero Mutual Water Company
site RTU Name RTU-21 90% RTU-21 20240124 LAD 13 - MISC --- Total Rungs in File = 9
site Plant Name Santa Ana 90% N15:1 12 Santa Ana Comm Fail Reset HS2100E
site Plant Name El Monte 90% N16:1 12 El Monte Comm Fail YA2197
site RTU Identifier RTU-21 90% RTU-21 20240124 LAD 5 - SCADA OUT
site Well 25 PLC Well 25 90% Well 25 PLC has inputs landed at I:0/3, I:0/4, I:0/5 for UPS status
site RTU-06 RTU-06 90% mapped to RTU-06
site Well 5a PLC Well 5a 90% Well 5a PLC has an input landed at I:1/5 labelled Well 5a High Discharge Pressure
site RTU Name RTU-21 90% RTU-21 20240124 LAD 11 - PUMP2
site Location El Monte 80% Level Mode YN2100D El Monte Comm Fail YA2197
site Location Santa Ana 80% LES Santa Ana Level LN0511
site Plant Location El Monte 80% Level Mode YN2100D LES Less Than (A<B) Source A N15:27 211< Source B N15:28 195< LES El Monte Level LN3211
site Select Summit Hills Feedback select summit hills feedback 80% select summit hills feedback
site Plant Location Santa Ana 80% LES Santa Ana Level LN0511 EN DN TON Timer On Delay Timer T9:25
site site description sites with 900mhz radios 70% When my computer plugs into one of these sites all of the 900mhz radios go down.
system Ethernet Switch Model 108TX-MDR 100% ENET SWITCH 108TX-MDR
system PLC Model 1769-L24ER-QBFC1B 100% COMPACTLOGIX [1769-L24ER-QBFC1B]
system Pump Name Pump 1 100% Pump 1
system Analog Input Module 1769-IF8 100% ANALOG INPUT SLOT 1 WIRING DIAGRAM 1769-IF8
system Analog Output Module 1769-OF4 100% ANALOG OUTPUT SLOT 2 WIRING DIAGRAM 1769-OF4
system HMI Model RED LION 100% 7IN TOUCHSCREEN RED LION
system SCADA System SCADA 95% LAD 4 - SCADA IN --- Total Rungs in File = 16
system Pump 1 P1 (Pump 1) 90% 0-3: P1 (Pump 1) states: running, fail, Auto, hand
system SCADA application FactoryTalk SE 90% The SCADA application is FactoryTalk SE
system PLC Module 1746-NI8 90% Initialization for Slot 5 - 1746-NI8 - Analog 8 Channel Input
system PLC Tag Prefix N16 90% Source A N16:15 EQU Pump Stage HI2111
system Timer Tags T9:5 to T9:10 90% RES T9:5 Stage 1 Stepup Timer ... RES T9:10 Stage 1 Stepdown Timer
system Pump Identifiers Pump 1, Pump 2, Pump 3 90% Pump 1 in Auto YN2101A, Pump 2 in Auto YN2102A, Pump 3 in Auto YN2103A
system Pump Lead/Lag Tags HIK2100A, HIK2100B, HIK2100C 90% Lead Pump HIK2100A, Lag 1 Pump HIK2100B, Lag 2 Pump HIK2100C
system PLC Programming Software RSLogix 5000 v36.00 90% Version = RSLogix 5000 v36.00
system PLC Module 1746-OW8 90% O:2 2 1746-OW8 Pump 3 Call
system Phoenix Contact Phoenix Contact 90% Phoenix Contact logo with the tagline "INSPIRING INNOVATIONS"
system Pump 2 P2 (Pump 2) 90% 4-7: P2 (Pump 2) states: running, fail, Auto, hand
system Pump 3 P3 (Pump 3) 90% 8-11: P3 (Pump 3) states: running, fail, Auto, hand
system product name rslogix500 90% there are zero emulation options for rslogix500 that I can find
system product name tailscale 90% 13:40 Kevin: really? is it your tailscale causing a storm?
system data concentrator hardware Controllogix 85% There is a data concentrator (controllogix) that compares field data reads
system Chlorine Sensor Cl2 (Chlorine) 85% 4: Cl2 (Chlorine) ✓
system Alarms comm fail, low, high, level fail, flow LO LO, LO, hi, fail, discharge LO, discharge hi, discharge fail, suction LO, suction hi, suction fail, Cl2 LO, Cl2 hi 80% comm fail, low, high, level fail, flow LO LO, LO, hi, fail
system PLC Model 1746-OW8 80% O:2 0 1746-OW8 Pump 1 Call
system PID Control System Pressure_PID 80% Pressure_PID/Pump_Routine.pdf
system Device Model HS2100F 80% El Monte Comm Fail Reset HS2100F
system Device Model HS2100E 80% Santa Ana Comm Fail Reset HS2100E
system Intrusion AIM Alarm intrusion AIM 80% intrusion AIM ✓
system Power Fail Alarm power fail 80% power fail, low suction, low level shutdown
system PLC Model 1746-IB16 80% 1746-IB16 Power Fail
system PLC Controller CompactLogix 80% Tags like Local:1:C and AB:Embedded_DiscreteIO1:C:0 indicate CompactLogix
system Pump Auto Alternation Tag B3:1 0 Auto Alt 80% B3:1 0 Auto Alt N15:1 8 Pump Auto Alt HS2100A
system Pump Model Lag 2 Pump HIK2100C 80% MOV Lag 2 Pump HIK2100C MOV Move Source
system Pump Model Lag 1 Pump HIK2100B 80% MOV Lag 1 Pump HIK2100B MOV Move Source
system Pump Model Lead Pump HIK2100A 80% MOV Lead Pump HIK2100A MOV Move Source
system PLC Model 1746-IB16 80% 1746-IB16 Entry Switch EN DN TON Timer On Delay
system PLC Model 1746-OW8 80% O:2 1 1746-OW8 Pump 2 Call
system Input Tags N16:1, N16:2, N16:3, N16:7, N16:8, N15:1, N15:8, N15:9, N12:26, N7:8 80% N16:1, N16:2, N16:3, N16:7, N16:8, N15:1, N15:8, N15:9, N12:26, N7:8
system Output Tags O:2/0, O:4.0 80% O:2 0 1746-OW8 Pump 1 Call; O:4.0 VFD 1 Speed CMD
system PLC Timer Tags T9:11, T9:12, T9:13, T9:14, T9:19, T4:18 80% Timer T9:11, T9:12, T9:13, T9:14, T9:19, T4:18
system SCADA studio software FactoryTalk Studio and Win911 config software 80% One of the computers at the SCADA room (the right one) has studio, and Win911 config software
system SCADA runtime licenses three separate SE runtime licenses, one studio license 80% AMWC has three separate SE runtime licenses, one studio license
system field HMIs Red Lion HMIs with proprietary comm adapter 75% Red Lion HMIs in the field with a proprietary comm adapter
system SCADA System SCADA OUT 70% LAD 5 - SCADA OUT --- Total Rungs in File = 10
task Flow Total Reset HS2111 80% Flow Total Reset HS2111 CLR Dest N16:13
task Power Usage Reset HS2191 80% Power Usage Reset HS2191 RES C5:0
task Pump 3 Starting Timer Timer T9:24 with preset 60 seconds 80% T9:24 Time Base 1.0 Preset 60< Accum 0< TON Pump 3 Starting Timer
task Alarm Activation Condition Activate alarms only if analog signal is not out of range and the alarms setpoint is greater than the minimum setpoint 80% Activate alarms only if analog signal is not out of range and the alarms setpoint is greater than the minimum setpoint
task Pump 3 Run YN2103 80% Pump 3 Run YN2103
task Pump 1 Run YN2101 80% Pump 1 Run YN2101
task Pump 3 Backspin Timer Timer T9:21 with preset 15 seconds 80% T9:21 Time Base 1.0 Preset 15< Accum 15< TON Pump 3 Backspin Timer
task Pump 3 Fail to Start Timer Timer T9:22 with preset 30 seconds 80% T9:22 Time Base 1.0 Preset 30< Accum 0< TON Pump 3 FTS Timer
task Pump 3 Runtime Timer Timer T9:23 with preset 3600 seconds 80% T9:23 Time Base 1.0 Preset 3600< Accum 3248< RTO Pump 3 Runtime
task Pump 2 Run YN2102 80% Pump 2 Run YN2102
task Pump 2 Runtime Timer T9:18 70% T9:18 DN Pump 2 Runtime
task Pump 2 Fail to Start Timer T9:17 70% T9:17 DN Pump 2 FTS Timer
vpn WireGuard client download URL https://www.wireguard.com/install/ 100% The WireGuard client can be downloaded at https://www.wireguard.com/install/
vpn Wireguard VPN config download URL https://send.bitwarden.com/#ECvdnVWLMk-xE7QEAXSiJg/1RTYfr1rEOqeoicaixECkA 100% use the updated file here: https://send.bitwarden.com/#ECvdnVWLMk-xE7QEAXSiJg/1RTYfr1rEOqeoicaixECkA
vpn VPN Endpoint SYC1.AMWC.US:51820 100% Endpoint = SYC1.AMWC.US:51820
vpn VPN config file URL https://send.bitwarden.com/#ECvdnVWLMk-xE7QEAXSiJg/1RTYfr1rEOqeoicaixECkA 90% use the updated file here: https://send.bitwarden.com/#ECvdnVWLMk-xE7QEAXSiJg/1RTYfr1rEOqeoicaixECkA