| contact |
Person 1 |
Kevin |
100% |
09:20 [Kevin]: can you log in and check the PLC |
| contact |
Person |
Mason Radke |
100% |
09:18 [Mason Radke] |
| contact |
Person |
Kevin |
100% |
09:23 [Kevin] |
| contact |
Person |
Mason Radke |
100% |
**08:47 [Mason Radke]** lets see what i can find |
| contact |
Person |
Kevin |
100% |
**08:46 [Kevin]** I think this power supply in the middle comes out. |
| contact |
person name |
Kevin |
100% |
**08:30 [Kevin](https://slack.com/archives/C08HMJX8J4F/p1760628640902479):** @Mason Radke message from Trevor. |
| contact |
person name |
Mason Radke |
100% |
**08:31 [Mason Radke](https://slack.com/archives/C08HMJX8J4F/p1760628669905449):** Yes sir |
| contact |
Person 2 |
Mason Radke |
100% |
09:20 [Mason Radke]: ok yeah |
| contact |
email |
email@autosysnet.com |
90% |
what are you using the <mailto:email@autosysnet.com|email@autosysnet.com> account for? |
| credential |
MSSQL SA Login |
user: SA / password: SolvangAdmin17 |
95% |
im not sure: MSSQL SA SolvangAdmin17 |
| credential |
Server Login |
username: autosys / password: @ut0sys! |
90% |
could try to log into the server with autosys/@ut0sys! |
| _no_entities |
none_found |
|
0% |
|
| _no_entities |
none_found |
|
0% |
|
| _no_entities |
none_found |
|
0% |
|
| _no_entities |
none_found |
|
0% |
|
| server |
HMI IP Address 2 |
192.168.50.111 |
90% |
i think i see the HMI at 192.168.50.111 |
| server |
HMI IP Address 1 |
192.168.50.101 |
90% |
can you vnc to the hmi? ... 192.168.50.101 |
| server |
SCADA VM server |
5 years old VM server with nearly full hard drive |
80% |
the server is 5 years old and they need to put money in the budget |
| server |
Database Server |
SQL Server |
80% |
SQL Server does it all |
| server |
DEV machine environment |
Windows 7 VM |
80% |
Its an old Win7 VM |
| server |
Router |
router |
70% |
I will have them reboot the router |
| server |
SMTP Server |
SMTP server |
70% |
probably an outgoing limit on the SMTP server that we're using |
| site |
plant name |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Plant |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Plant |
Solvang WWTP |
100% |
trouble at Solvang WWTP |
| site |
Client Plant |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Name |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Plant |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Name |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Client Name |
Solvang-WW |
100% |
Client: Solvang-WW |
| site |
Plant Name |
Fjord Lift Station |
90% |
# Fjord Lift Station.mer |
| site |
Client Name |
Solvang-WW |
90% |
Client: Solvang-WW |
| system |
HMI Product |
Automation Direct C-more HMI |
95% |
This specific C-more HMI error is a common communication fault |
| system |
Product Name |
FactoryTalk View ME |
95% |
FactoryTalk View ME runtime application file |
| system |
PLC Products |
Allen-Bradley ControlLogix, CompactLogix, MicroLogix |
95% |
Allen-Bradley (Rockwell Automation) ControlLogix, CompactLogix, or MicroLogix PLCs |
| system |
Reporting System |
SSRS (SQL Server Reporting Services) |
90% |
SSRS (SQL Server Reporting Services) |
| system |
FactoryTalk |
FactoryTalk |
90% |
having to remap all IO in FTView |
| system |
PLC Model Old |
L33E (5370) |
90% |
moving from *L33E (5370)* to *L320ER (5380)* |
| system |
PLC Model New |
L320ER (5380) |
90% |
moving from *L33E (5370)* to *L320ER (5380)* |
| system |
I/O Modules Old |
1769 Compact I/O |
90% |
your 1769 Compact I/O modules *cannot be reused directly* |
| system |
I/O Modules New |
5069 Compact I/O |
90% |
The L320ER is a *5380 series*, which requires *5069 Compact I/O* modules |
| system |
Control System |
Logix 5000 PLCs |
80% |
do you know which firmware version off the top of your head? for the 5000 plcs? |
| system |
Network Adapter |
1769-AENTR |
80% |
*1769-AENTR* will turn that IO rack into remote IO |
| system |
CompactLogix 5069 processor |
5069 processor |
80% |
converting this program to the new 5069 processor |
| system |
PLC System |
Micrologix or SLC |
70% |
looks like this was translated from a micrologix? Could be, or a SLC |
| system |
FactoryTalk |
FactoryTalk installation files |
70% |
deleted some of the FT installation files |
| task |
Check Tag Definitions |
Verify tag names and scope on C-more panel to fix PLC-498 error |
90% |
Check Tag Name Spelling and Case ... Verify Tag Scope ... Delete unused tags |
| task |
Onsite availability |
Mason Radke onsite at Solvang Tuesday |
90% |
are you available tuesday to be onsite at Solvang? |
| task |
PLC swap |
Postponed until Tuesday |
90% |
Postpone until Tues. You should have received an updated calendar event? |
| task |
Identify Offending Tag |
Use C-more panel system menu to find specific tags causing PLC-498 fault |
90% |
press and hold upper-left corner ... Error List ... specific tag names |
| task |
Thin out SBR3 datalog |
Evaluate and reduce SBR3 datalog size |
90% |
I created a task for us to thin this out and maybe evaluate what it is recording |
| task |
Rebuild DEV machine |
Rebuild the DEV machine for Solvang WW |
90% |
assignment I put in smartsheet for you to rebuild the DEV machine for Solvang ww |
| task |
PLC Backup Setup |
Get another PLC or buy a used one and set it up as backup |
80% |
We need to get another PLC in there, or buy another used one and set it up as a backup |
| vpn |
VPN Access |
VPN |
80% |
i cant connect through our VPN or RUT |